Skip to content
VoltCalcElectrical Calculators & Tools
Electrical Terms Explained Simply

Electrical Glossary

Explore a comprehensive glossary of electrical terms, formulas, units, and technical concepts. Understand AC and DC electricity, electrical power, voltage, current, resistance, wiring, batteries, solar systems, and more.

Search by term, symbol, SI unit, or abbreviation — try:
Definitions & Formulas
A–Z Reference
Verified engineering definitions & formulas
Technical Categories
Core Domains
Core domains from fundamentals to solar PV
Alphabetical Index
A–Z Jump Bar
Alphabetically indexed A–Z reference
Standards Context
AC & DC Systems
Dual NFPA 70 (NEC) & IEC 60364 / BS 7671 context
Glossary Topics

Browse by Category

Browsing all glossary terms

All Electrical Glossary Terms

A

Terms Starting with A

AC

Alternating Current (AC)

Electric current that periodically reverses its direction of flow and changes magnitude continuously over time, typically at 50 Hz or 60 Hz. Unlike Direct Current (DC), AC voltage can be stepped up or down efficiently with transformers for long-distance grid transmission and drives induction motors directly.

Symbol: ACSI Unit: ampere (A) / hertz (Hz)
Formula: v(t) = V_peak × sin(2πft)

Example: A 230 V RMS 50 Hz mains supply swings between +325 V and −325 V fifty times every second.

Related terms:
AC & DC

American Wire Gauge (AWG / kcmil) ↔ IEC 60228 (mm²)

Cross-standard conductor sizing: North America (NFPA 70 NEC / ASTM B258) uses logarithmic American Wire Gauge (30 AWG to 4/0 AWG) and circular mils (250–1000 kcmil), whereas International & UK standards (IEC 60228 / BS EN 60228) specify nominal cross-sectional area in square millimeters (1.5 mm² to 300+ mm²) defined by maximum 20 °C DC resistance (R₂₀ in Ω/km). Never mix metric ferrules or lugs into imperial AWG terminals unless dual-listed.

Symbol: AWG / kcmil ↔ mm²SI Unit: gauge / mm²
Formula: d_n = 0.127 mm × 92^((36−n)/39) | Every 3 AWG steps ≈ 2× area

Example: 12 AWG copper (3.31 mm²) is the closest AWG size below 4.0 mm² IEC; when converting a metric design to NEC, upsize to the next larger standard size and verify ampacity & voltage drop.

Related terms:
AC & DC

Ampacity (Iz)

The maximum current, in amperes, that a conductor can carry continuously under its conditions of use without exceeding its insulation temperature rating (called Ampacity in NFPA 70 NEC 310.16 and Current-Carrying Capacity Iz in IEC 60364-5-52 / BS 7671 Appendix 4).

Symbol: Iz / I_tableSI Unit: ampere (A)
Formula: I_z = I_table × C_a (temp) × C_g (grouping)

Example: A 3 AWG copper conductor rated for 100 A at 75 °C (or 25 mm² copper rated ~101 A Method C) must be derated if installed in a 45 °C ambient conduit with multiple circuits.

Related terms:
AC & DC

Ampere (A)

The SI base unit of electric current, equal to one coulomb of electric charge passing a cross-section of a conductor in one second. Distinguish the unit (ampere, symbol A) from the physical quantity it measures (electric current, symbol I).

Symbol: ASI Unit: ampere (A)
Formula: 1 A = 1 C / s

Example: A 2,400 W resistive heater operating on a 240 V circuit draws I = 2,400 ÷ 240 = 10 A.

Related terms:
DC

Ampere-Hour (Ah) vs. Watt-Hour (Wh)

Ampere-hours (Ah) measure electric charge capacity (current multiplied by hours), whereas watt-hours (Wh) measure true stored energy (charge multiplied by nominal voltage, Wh = Ah × V). You cannot compare the energy of two batteries using Ah alone unless both operate at the exact same nominal voltage.

Symbol: Ah ↔ WhSI Unit: ampere-hour (Ah) / watt-hour (Wh)
Formula: E (Wh) = C (Ah) × V_nominal | 1 kWh = 1,000 Wh

Example: A 100 Ah battery at 12 V stores 1,200 Wh (1.2 kWh), whereas a 100 Ah battery at 48 V stores 4,800 Wh (4.8 kWh)—four times the energy.

Related terms:
AC

Apparent Power (VA)

The vector magnitude of total power in an AC circuit, equal to the product of RMS voltage and RMS current without considering phase angle. Unlike real power (watts), which performs actual work, apparent power (VA / kVA) sizes transformers, UPS units, and generators because their windings must carry the full current.

Symbol: SSI Unit: volt-ampere (VA / kVA)
Formula: S = V × I (1φ) | S = √3 × V_LL × I_L (3φ) | S = √(P² + Q²)

Example: A load drawing 10 A at 120 V has an apparent power of 1,200 VA (1.2 kVA), even if its real working power is 960 W at 0.80 power factor.

Related terms:
AC & DC

Arc Fault (AFCI / AFDD)

A high-power luminous discharge of electricity across an insulating medium caused by damaged insulation, pinched cables, or loose terminals. Arc Fault Circuit Interrupters (NEC AFCI) and Arc Fault Detection Devices (IEC 62606 AFDD) analyze high-frequency current waveforms to trip before an arc ignites surrounding material.

Symbol: AFCI / AFDDSI Unit: ampere (A)

Example: A staple driven through a wall cable can cause a series arc that draws only 5 A—too low to trip a 15 A thermal breaker, but detected by an AFCI/AFDD.

Related terms:
B

Terms Starting with B

DC

Battery Charge / Discharge Rate (C-Rate)

A normalized measure of the current at which a battery is charged or discharged relative to its nominal ampere-hour capacity. A 1C rate charges or discharges the full nominal capacity in 1 hour; 0.2C (C/5) takes 5 hours; and 0.05C (C/20) takes 20 hours.

Symbol: C-rateSI Unit: 1 / hour (C)
Formula: I (A) = C_rate × Capacity (Ah) | t (h) ≈ 1 ÷ C_rate

Example: For a 200 Ah battery bank, a 0.5C discharge current is 100 A, while a 0.2C charge current is 40 A.

Related terms:
DC

Battery Chemistry (LiFePO4 vs. Lead-Acid / AGM)

Stationary energy storage banks predominantly use Lithium Iron Phosphate (LiFePO4, 3.2 V nominal per cell, 80–90% usable DoD, 3,000–6,000+ cycles) or Valve-Regulated Lead-Acid (AGM/Gel, 2.0 V nominal per cell, 50% recommended DoD, 400–1,200 cycles). Different chemistries have distinct absorption voltages and must never be wired directly in parallel without dedicated DC conversion.

Symbol: LiFePO4 / VRLASI Unit: V / cell
Formula: 12 V Nominal: 4S LiFePO4 = 12.8 V | 6-Cell Lead-Acid = 12.0 V

Example: Replacing a 200 Ah lead-acid bank (50% DoD = 100 Ah usable) requires only a 120 Ah LiFePO4 bank (85% DoD = 102 Ah usable) to deliver the same runtime.

Related terms:
DC

Battery Management System (BMS)

An electronic protection and monitoring unit integrated into lithium (LiFePO4 / Li-ion) battery packs that tracks individual cell voltages, balances charge across series cells, and opens solid-state or contactor switches on over-voltage, under-voltage, over-current, short-circuit, or unsafe cell temperatures.

Symbol: BMSSI Unit: ampere (A) / volt (V)

Example: A 12.8 V 100 Ah LiFePO4 battery with a 100 A BMS limits continuous discharge to 1,280 W and blocks charging when cell temperature falls below 0 °C.

Related terms:
AC & DC

Breaking Capacity (Icn / AIC)

The maximum prospective fault current that a circuit breaker or fuse can safely interrupt at its rated voltage without rupturing or welding its contacts shut (termed Ampere Interrupting Capacity AIC under NEC 110.9/UL 489, and Rated Short-Circuit Capacity Icn or Icu under IEC 60898-1/IEC 60947-2).

Symbol: Icn / Icu / AICSI Unit: kiloampere (kA)

Example: Residential branch breakers are commonly rated at 10 kA AIC (or 6 kA / 10 kA Icn under IEC), whereas industrial molded-case breakers may be rated from 25 kA to 65 kA.

Related terms:
AC & DC

Busbar

A rigid solid copper or aluminum metallic bar inside a switchboard, panelboard, consumer unit, or DC battery distribution cabinet that distributes high currents to multiple outgoing branch breakers or fuse ways with minimal impedance and high short-circuit dynamic withstand capability.

Symbol: I_busSI Unit: ampere (A) / mm²
Formula: R_bus = ρ × L ÷ (W × T) (Width × Thickness cross-section)

Example: A 48 V DC battery bank uses a tin-plated copper busbar rated at 400 A to parallel two inverter cables and an MPPT charge controller with equal cable lengths.

Related terms:
C

Terms Starting with C

AC & DC

Capacitance

The property of a component or circuit that allows it to store electrostatic energy in an electric field between two conductive plates separated by a dielectric insulator. Capacitors block steady-state DC while passing AC current inversely proportional to frequency.

Symbol: CSI Unit: farad (F / µF)
Formula: Q = C × V | E = ½ × C × V²

Example: A 470 µF capacitor charged to 50 V DC stores E = 0.5 × 0.00047 × 2,500 = 0.588 J of energy.

Related terms:
AC

Capacitive Reactance (Xc)

The frequency-dependent opposition that a capacitor presents to alternating current, measured in ohms. Capacitive reactance causes current to lead voltage by 90° in an ideal capacitor, decreases as frequency or capacitance rises, and approaches infinity (an open circuit) at 0 Hz DC.

Symbol: X_CSI Unit: ohm (Ω)
Formula: X_C = 1 ÷ (2πfC)

Example: A 10 µF capacitor on a 60 Hz AC circuit has a capacitive reactance of X_C = 1 ÷ (2π × 60 × 0.00001) = 265.3 Ω.

Related terms:
AC & DC

Circuit Breaker (CB ↔ MCB / MCCB)

A resettable overcurrent protective device that automatically opens a circuit when current exceeds its thermal (overload) or magnetic (short-circuit) threshold. In North America (NFPA 70 NEC Article 240 / UL 489), branch circuit breakers are rated by continuous current (In) and interrupting rating (AIC); in IEC 60898-1 / BS 7671 installations, DIN-rail Miniature Circuit Breakers (MCBs) are classified by instantaneous magnetic trip curve (Type B: 3–5× In, Type C: 5–10× In, Type D: 10–20× In).

Symbol: CB / MCBSI Unit: ampere (A)
Formula: I_b (design load) ≤ I_n (breaker rating) ≤ I_z (conductor ampacity)

Example: A 20 A Type B MCB (IEC) or 20 A UL 489 branch breaker (NEC) carries 20 A continuously and trips magnetically in milliseconds on a short circuit.

Related terms:
AC & DC

Conductance

The ease with which electric current flows through a material—mathematically the reciprocal of electrical resistance (G = 1 ÷ R). In parallel resistive circuits, individual branch conductances add directly to yield total circuit conductance.

Symbol: GSI Unit: siemens (S)
Formula: G = 1 ÷ R = I ÷ V

Example: A 10 Ω resistor has a conductance of G = 1 ÷ 10 = 0.1 S (100 mS).

Related terms:
AC & DC

Continuous Load & Demand Diversity (NEC Art. 120/220 ↔ IEC ks)

Cross-standard load & feeder sizing: Under NFPA 70, loads sustained for ≥3 hours require 125% branch sizing, while service/feeder demand uses NEC 2026 Article 120 (formerly NEC 2023 Article 220), Table 120.54 dryer demand, and Section 120.7 Power Control Systems (PCS). Under IEC 60364 / BS 7671, maximum demand (Ib) applies circuit-group simultaneity/diversity factors (ks, ku) and 3-phase L1/L2/L3 balance checks.

Symbol: 125% Rule ↔ ksSI Unit: ampere (A) / VA
Formula: NEC: I_circuit = 1.25 × I_cont + 1.00 × I_noncont | IEC: I_b = ∑ (I_load × k_u) × k_s

Example: A 40 A continuous Level 2 EVSE requires a 50 A circuit under NEC (40 × 1.25), or can be managed below a busbar limit using an NEC 2026 Section 120.7 listed PCS.

Related terms:
AC & DC

Coulomb & Electric Charge (Q)

Electric charge (quantity symbol Q) is the fundamental physical property of matter that causes it to experience a force in an electromagnetic field; its SI derived unit is the coulomb (unit symbol C). One coulomb equals the charge transported by a constant current of one ampere in one second (≈ 6.242 × 10¹⁸ elementary charges).

Symbol: Q / CSI Unit: coulomb (C)
Formula: Q = I × t = C × V | 1 Ah = 3,600 C

Example: A steady current of 2 A flowing for 30 seconds transfers Q = 2 × 30 = 60 C of electric charge.

Related terms:
AC & DC

Current

The rate at which electric charge flows past a given point in an electrical circuit, measured in amperes (A). Whereas voltage is the potential difference (electrical pressure) across two points, current is the actual flow of charge through the conductor that performs work and causes I²R heating.

Symbol: ISI Unit: ampere (A)
Formula: I = V ÷ R | I = P ÷ V (DC) | I = P ÷ (V × PF) (1φ AC)

Example: A 1,500 W appliance on a 120 V supply draws I = 1,500 ÷ 120 = 12.5 A.

Related terms:
D

Terms Starting with D

DC

DC-to-DC Converter (Buck / Boost)

A high-frequency switching power-electronic circuit that steps a direct current (DC) voltage down (buck converter) or up (boost converter) to a different regulated DC voltage level with minimal energy loss, acting as the DC equivalent of an AC transformer.

Symbol: DC / DCSI Unit: volt (V) / ampere (A)
Formula: P_out = P_in × η | V_out × I_out = V_in × I_in × η

Example: A 48 V-to-12 V buck converter at 95% efficiency delivering 20 A at 12 V (240 W) draws only 5.26 A from the 48 V battery bank.

Related terms:
AC & DC

Demand Factor & Diversity Factor

The ratio of the maximum simultaneous electrical power demand of a system (or group of loads) to the total connected nameplate load. Because not all appliances, outlets, or motors in a building operate at 100% full load at the exact same moment, electrical codes (NEC Article 220 and IEC 60364 / BS 7671 Appendix A) apply demand/diversity factors when sizing main service feeders.

Symbol: K_dSI Unit: ratio (0 to 1) or percent (%)
Formula: Demand Factor = Maximum Coincident Demand (kW) ÷ Total Connected Load (kW)

Example: A residence with 45 kW of total connected appliance ratings and a peak simultaneous demand of 18 kW operates at a 0.40 (40%) demand factor.

Related terms:
DC

Depth of Discharge (DoD)

The percentage of a battery’s nominal capacity that has been removed relative to its fully charged state (the inverse of State of Charge, DoD = 100% − SoC). Limiting maximum DoD prevents plate sulfation in lead-acid cells and extends total cycle life across all battery chemistries.

Symbol: DoDSI Unit: percent (%)
Formula: Usable Wh = Nominal Wh × DoD

Example: A 12 V 100 Ah (1,200 Wh) AGM battery limited to 50% DoD provides 600 Wh of usable energy, whereas a LiFePO4 battery at 80% DoD provides 960 Wh.

Related terms:
AC & DC

Dielectric Strength

The maximum electric field intensity that an insulating material (such as cable PVC/XLPE insulation, air, or transformer mineral oil) can withstand intrinsically without suffering dielectric breakdown and becoming electrically conductive.

Symbol: E_bdSI Unit: kV / mm

Example: Dry transformer mineral oil is routinely tested to ensure its breakdown voltage exceeds 30 kV across a 2.5 mm electrode gap.

Related terms:
AC & DC

Diode & Bridge Rectifier

A two-terminal semiconductor device (PN junction) that conducts electric current primarily in one direction (forward bias above its forward voltage drop Vf ≈ 0.7 V for silicon or 0.3 V for Schottky) and blocks current in the reverse direction. Four diodes arranged in a bridge rectifier convert alternating current (AC) into pulsating direct current (DC).

Symbol: D / VfSI Unit: volt (V) / ampere (A)
Formula: V_dc_peak ≈ V_ac_rms × √2 − (2 × V_f)

Example: A full-wave silicon bridge rectifier fed by 24 V RMS AC charges a filter capacitor to a peak DC voltage of (24 × 1.414) − 1.4 = 32.5 V DC.

Related terms:
DC

Direct Current (DC)

Electric current that flows unidirectionally with constant polarity. Unlike AC circuits, steady-state DC circuits have zero frequency (f = 0 Hz), meaning no inductive or capacitive reactance exists and power is strictly the product of voltage and current (P = V × I). Batteries, solar PV modules, LEDs, electronics, and EV traction packs operate on DC.

Symbol: DCSI Unit: volt (V) / ampere (A)
Formula: P = V × I = I² × R = V² ÷ R

Example: A 48 V DC solar battery bank delivering 50 A supplies 2,400 W to an inverter.

Related terms:
E

Terms Starting with E

AC

Earth Fault Loop Impedance (Zs)

The total impedance of the earth fault path starting at the point of fault, travelling back through the circuit protective conductor (R2) and external earth return path (Ze) to the supply transformer winding, and returning along the phase conductor (R1). Under IEC 60364-4-41 and BS 7671, Zs must be low enough for the protective device to trip within 0.4 s (final circuits) or 5 s (distribution circuits).

Symbol: Z_sSI Unit: ohm (Ω)
Formula: Z_s = Z_e + (R₁ + R₂) | Z_s_max = (U₀ × C_min) ÷ I_a

Example: With external impedance Ze = 0.35 Ω and cable R1+R2 = 0.45 Ω, total loop impedance is Zs = 0.80 Ω, well below the 1.37 Ω limit for a 32 A Type B MCB at 230 V.

Related terms:
AC & DC

Efficiency

The dimensionless ratio of useful output power to total input power, usually expressed as a percentage. Because of conservation of energy, η is always less than 100% in real equipment; the difference (P_in − P_out) is dissipated primarily as heat from I²R winding losses, core hysteresis, and switching losses.

Symbol: ηSI Unit: percent (%)
Formula: η = (P_out ÷ P_in) × 100%

Example: An electric motor delivering 7.5 kW mechanical shaft output while drawing 8.5 kW electrical input has an efficiency of 88.2%.

Related terms:
AC & DC

Electric Field & Potential Difference

An electric field (E) is the physical force field surrounding electric charges that exerts a force on other charges (F = qE). Potential difference (ΔV, commonly called voltage) is the work required per unit charge to move a test charge between two points within that field.

Symbol: E / ΔVSI Unit: volt per meter (V/m)
Formula: E = ΔV ÷ d | W = Q × ΔV

Example: A potential difference of 500 V across a 2 mm air gap produces an electric field strength of 250,000 V/m (0.25 kV/mm).

Related terms:
AC & DC

Electric Motor (Induction & Synchronous)

An electromechanical machine that converts electrical power into mechanical shaft torque and rotation via interacting magnetic fields between the stationary stator and rotating rotor. AC squirrel-cage induction motors rotate slightly slower than synchronous speed (slip), whereas synchronous and brushless permanent-magnet motors lock to stator frequency.

Symbol: MSI Unit: kilowatt (kW) / horsepower (hp)
Formula: P_elec_in = P_shaft_out ÷ η | T (N·m) = (9550 × P_kW) ÷ RPM

Example: A 15 kW 4-pole motor running at 1,460 RPM develops T = (9,550 × 15) ÷ 1,460 = 98.1 N·m of shaft torque.

Related terms:
AC & DC

Electromotive Force (EMF)

The open-circuit electrical potential generated by an energy-converting source—such as an electrochemical battery cell, generator winding, or photovoltaic junction—before any current flows. Under load, terminal voltage drops below EMF due to the source’s internal resistance.

Symbol: E / εSI Unit: volt (V)
Formula: V_terminal = E − (I × R_internal)

Example: A starter battery with an open-circuit EMF of 12.6 V and internal resistance of 0.02 Ω drops to 10.6 V at its terminals while supplying 100 A.

Related terms:
AC & DC

Energy

The total capacity to do work or the cumulative amount of electrical power transferred over a period of time (Energy = Power × Time). Do not confuse power (watts or kilowatts, an instantaneous rate) with energy (watt-hours or kilowatt-hours, the accumulated total billed by utilities).

Symbol: ESI Unit: kilowatt-hour (kWh) / joule (J)
Formula: E (kWh) = P (kW) × t (hours) | 1 kWh = 3.6 × 10⁶ J

Example: A 1,500 W (1.5 kW) space heater running for 4 hours consumes 1.5 × 4 = 6 kWh of electrical energy.

Related terms:
AC & DC

Equipotential Bonding vs. Grounding (Earthing)

Distinguishing two essential safety functions: Bonding connects exposed metal parts and extraneous conductive services (metallic water pipes, structural steel, enclosures) together so no dangerous voltage difference can exist between two surfaces a person might touch simultaneously. Grounding (NEC) or Earthing (IEC/BS 7671) connects the electrical system to the general mass of the Earth via electrodes and provides a low-impedance fault return path back to the source to trip overcurrent protection.

Symbol: Bonding ↔ EarthingSI Unit: ohm (Ω) / mm²
Formula: R_bond ≤ 50 V ÷ I_a (Supplementary bonding touch-voltage rule)

Example: Main protective bonding conductors (IEC Table 54.8) or bonding jumpers (NEC 250.102) tie main metallic water and gas entry pipes to the main earthing terminal.

Related terms:
F

Terms Starting with F

AC & DC

Farad (F)

The SI derived unit of electrical capacitance. A one-farad capacitor stores one coulomb of electric charge when a potential difference of one volt is applied across its plates. Because 1 F is very large, circuit capacitors are normally rated in microfarads (µF, 10⁻⁶ F), nanofarads (nF, 10⁻⁹ F), or picofarads (pF, 10⁻¹² F).

Symbol: FSI Unit: farad (F)
Formula: 1 F = 1 C / V = 1 s / Ω

Example: A single-phase HVAC compressor run capacitor is commonly rated between 5 µF and 60 µF at 370 V or 440 V AC.

Related terms:
AC & DC

Fault Current

The abnormal current that flows through an electrical system during a short circuit (line-to-neutral or line-to-line) or an earth/ground fault (line-to-PE/EGC). Prospective fault current is highest near the supply transformer terminals and attenuates with cable length due to conductor impedance.

Symbol: I_psc / I_scSI Unit: kiloampere (kA)
Formula: I_fault = V_supply ÷ Z_loop

Example: If the total fault loop impedance on a 230 V circuit is 0.23 Ω, the prospective fault current is 230 ÷ 0.23 = 1,000 A (1 kA).

Related terms:
AC

Frequency

The number of complete alternating current cycles completed in one second, measured in hertz (Hz). Standard utility grid frequency is 60 Hz in North America and parts of South America, and 50 Hz across Europe, the UK, Asia, Africa, and Australia.

Symbol: fSI Unit: hertz (Hz)
Formula: f = 1 ÷ T | ω = 2πf (rad/s)

Example: At 50 Hz, each complete AC sine wave cycle takes T = 1 ÷ 50 = 0.02 s (20 milliseconds).

Related terms:
AC & DC

Fuse

A single-use overcurrent protection device containing a calibrated fusible metal element surrounded by arc-quenching silica filler that melts and vaporizes when excessive current flows for a specified duration. Current-limiting fuses (such as IEC gG/aM or UL Class J/RK1) can clear high-level short circuits with lower I²t let-through energy than standard thermal-magnetic breakers.

Symbol: FSI Unit: ampere (A)
Formula: I_n (fuse) ≥ 1.25 × I_cont (NEC) | I_b ≤ I_n ≤ I_z (IEC)

Example: A 250 V 150 A ANL or Class T DC fuse protects main battery cables connecting a 12 V battery bank to a 1,500 W inverter.

Related terms:
G

Terms Starting with G

AC & DC

Grid-Tied vs. Off-Grid Solar PV System

A grid-tied solar PV system synchronizes its inverter output directly with the utility AC grid (exporting surplus power and requiring anti-islanding rapid shutdown on grid loss unless paired with a hybrid battery). An off-grid PV system operates autonomously using a solar charge controller, battery bank sized for multi-day autonomy, and a standalone inverter.

Symbol: On-Grid ↔ Off-GridSI Unit: kilowatt (kW) / kWh
Formula: Battery Autonomy Wh = (Daily Load Wh × Autonomy Days) ÷ (DoD × η_inv)

Example: An off-grid cabin consuming 4 kWh/day with 2 days of autonomy on a 80% DoD LiFePO4 bank requires at least 11.1 kWh of battery capacity.

Related terms:
AC & DC

Grounding and Earthing (EGC ↔ PE / CPC)

Cross-standard protective bonding & fault return: North America (NEC Article 250) distinguishes the Equipment Grounding Conductor (EGC, fault return path sized per Table 250.122) from the Grounding Electrode Conductor (GEC, earth connection per Table 250.66). IEC 60364 & BS 7671 Section 543 designate the Protective Conductor (PE) or Circuit Protective Conductor (CPC), sized via Table 54.7 or the adiabatic equation S = √(I²t)/k and verified by Earth Fault Loop Impedance (Zs = Ze + R1 + R2).

Symbol: EGC ↔ PE / CPCSI Unit: ohm (Ω) / mm²
Formula: S_min = √(I² × t) ÷ k | Z_s = Z_e + (R₁ + R₂)

Example: On a 230 V TN system with a 32 A Type B MCB (Ia = 160 A), Zs must not exceed 1.37 Ω (at Cmin = 0.95) so a line-to-CPC fault disconnects within 0.4 s.

Related terms:
H

Terms Starting with H

AC

Harmonics (THD)

Sinusoidal currents or voltages at integer multiples of the fundamental AC supply frequency (such as 3rd harmonic at 150/180 Hz or 5th harmonic at 250/300 Hz) injected by non-linear switch-mode loads like VFDs, LED drivers, and computer power supplies. Total Harmonic Distortion (THD) quantifies waveform distortion and requires True-RMS meters for accurate measurement.

Symbol: THDSI Unit: percent (%)
Formula: THD (%) = (√(V₂² + V₃² + V₄² + ...) ÷ V₁) × 100%

Example: Triplen (3rd, 9th) harmonic currents in a 3-phase 4-wire system add constructively in the neutral conductor rather than cancelling out.

Related terms:
AC & DC

Henry (H)

The SI derived unit of electrical inductance (both self-inductance and mutual inductance). A coil has an inductance of 1 henry when an electric current changing at 1 ampere per second induces an electromotive force of 1 volt across it.

Symbol: HSI Unit: henry (H / mH)
Formula: V_L = L × (dI / dt) | 1 H = 1 V·s / A = 1 Ω·s

Example: A 50 mH (0.05 H) filter choke at 60 Hz presents an inductive reactance of X_L = 2π × 60 × 0.05 = 18.85 Ω.

Related terms:
AC

Hertz (Hz)

The SI derived unit of frequency, defined as one cycle per second (1 Hz = 1 s⁻¹). Named after physicist Heinrich Hertz, it quantifies the oscillation rate of AC power grids (50 Hz or 60 Hz), VFD motor drive outputs, and electronic switching converters.

Symbol: HzSI Unit: hertz (Hz)
Formula: 1 Hz = 1 cycle / second | T (s) = 1 ÷ f (Hz)

Example: A VFD ramping a 4-pole motor from 15 Hz to 60 Hz increases its synchronous speed from 450 RPM to 1,800 RPM.

Related terms:
AC & DC

Horsepower (hp)

A unit of mechanical shaft output power commonly used to rate electric motors in North America. One imperial mechanical horsepower equals exactly 745.699872 watts (≈ 746 W or 0.746 kW), whereas one metric horsepower (PS / cv) equals 735.5 watts.

Symbol: hpSI Unit: horsepower (hp)
Formula: 1 hp (mechanical) = 745.7 W = 0.746 kW | P_in (W) = (hp × 745.7) ÷ η

Example: A 5 hp motor at 88% efficiency delivers 3,728.5 W at the shaft while drawing 3,728.5 ÷ 0.88 = 4,237 W of electrical input power.

Related terms:
I

Terms Starting with I

AC

Impedance

The total opposition an AC circuit presents to alternating current at a given frequency, combining frequency-independent resistance (R) and frequency-dependent reactance (X = X_L − X_C) as a vector (phasor) sum. In DC circuits where f = 0 Hz, reactance vanishes and impedance simplifies to pure resistance (Z = R).

Symbol: ZSI Unit: ohm (Ω)
Formula: Z = √(R² + (X_L − X_C)²) | I = V ÷ Z

Example: A motor coil with 6 Ω winding resistance and 8 Ω inductive reactance has a total AC impedance of Z = √(6² + 8²) = 10 Ω.

Related terms:
AC & DC

Inductance

The property of an electrical conductor or coil by which a time-varying current creates a changing magnetic flux that induces an opposing electromotive force (back-EMF) in the conductor itself (self-inductance) or in an adjacent coil (mutual inductance). Inductors store energy in a magnetic field and oppose rapid changes in current.

Symbol: LSI Unit: henry (H)
Formula: E_stored = ½ × L × I² | V_L = L × (dI / dt)

Example: Motor windings, contactors, and transformer primaries have significant inductance, causing current to lag behind voltage in AC circuits.

Related terms:
AC

Inductive Reactance (XL)

The opposition presented to alternating current by an inductor’s changing magnetic field, measured in ohms. Inductive reactance is directly proportional to both AC frequency (f) and inductance (L), causes current to lag behind voltage by 90° in an ideal inductor, and equals 0 Ω at steady-state DC.

Symbol: X_LSI Unit: ohm (Ω)
Formula: X_L = 2πfL

Example: A 0.1 H inductor presents X_L = 2π × 50 × 0.1 = 31.42 Ω at 50 Hz, and 37.70 Ω at 60 Hz.

Related terms:
AC & DC

Inrush Current

The momentary high-magnitude surge of current drawn by electrical equipment—such as electric motors (Locked-Rotor Amps, LRA), transformers (magnetizing inrush), or switch-mode capacitor banks—when first energized before back-EMF or steady-state flux is established.

Symbol: I_inrush / LRASI Unit: ampere (A)
Formula: I_start ≈ (5 to 8) × I_FLA (Across-the-line induction motor)

Example: An induction motor with a full-load running current of 10 A typically draws 60 A to 80 A for several cycles during direct-on-line startup.

Related terms:
AC & DC

Insulation Resistance

The high electrical resistance measured in megohms (MΩ) between live conductors and protective earth—or between phase and neutral conductors—using a regulated DC insulation resistance tester (typically 250 V, 500 V, or 1,000 V DC per IEC 60364-6 / BS 7671 Table 64) to verify cable and winding insulation integrity.

Symbol: R_isoSI Unit: megohm (MΩ / GΩ)
Formula: Minimum R_iso ≥ 1.0 MΩ at 500 V DC (IEC 60364-6 / BS 7671 for LV circuits ≤500 V)

Example: New fixed building wiring tested at 500 V DC typically reads >200 MΩ; a reading dropping toward 1–2 MΩ indicates moisture ingress or insulation degradation.

Related terms:
DC

Internal Resistance (R_int)

The inherent opposition to current flow inside a practical voltage source (such as a battery cell, solar module, or DC power supply). Under load current I, internal resistance causes an internal voltage drop (I × R_int) and internal heat generation (I² × R_int), lowering the voltage available at the output terminals.

Symbol: R_int / ESRSI Unit: milliohm (mΩ) / ohm (Ω)
Formula: V_terminal = E_oc − (I_load × R_int)

Example: A 12.8 V battery with 15 mΩ (0.015 Ω) internal resistance drops by 1.5 V to 11.3 V during a 100 A inverter surge.

Related terms:
AC & DC

Inverter (DC to AC)

A power-electronic conversion unit that transforms direct current (DC) from a battery bank or solar PV array into alternating current (AC) at standard mains voltage and frequency (e.g., 120 V 60 Hz or 230 V 50 Hz). Pure Sine Wave (PSW) inverters synthesize low-THD AC suitable for sensitive electronics and inductive motor loads.

Symbol: DC → ACSI Unit: watt (W) / volt-ampere (VA)
Formula: I_dc = P_ac_out ÷ (V_dc × η_inv)

Example: A 2,000 W AC load powered from a 24 V battery bank through a 90% efficient pure sine wave inverter draws 2,000 ÷ (24 × 0.90) = 92.6 A DC.

Related terms:
J

Terms Starting with J

AC & DC

Joule (J)

The SI derived unit of energy, work, or quantity of heat. In electrical terms, one joule equals the energy expended when one watt of power is applied for one second (1 J = 1 W·s = 1 V · A · s).

Symbol: JSI Unit: joule (J)
Formula: E (J) = P (W) × t (s) = I² × R × t

Example: One kilowatt-hour (1 kWh) equals exactly 3,600,000 joules (3.6 MJ). Surge Protective Devices (SPDs) are often rated by joules of transient energy absorption.

Related terms:
AC & DC

Joule Heating (I²R Loss)

The physical process by which electric current passing through a conductor with resistance R converts electrical energy directly into thermal energy at a rate proportional to the square of the current (P = I²R). Because heating scales with I², doubling the current quadruples conductor heat dissipation.

Symbol: P_loss = I²RSI Unit: watt (W) / BTU/h
Formula: P_heat (W) = I² × R | Q_heat (J) = I² × R × t

Example: A cable with 0.2 Ω resistance carrying 30 A dissipates 30² × 0.2 = 180 W of heat; increasing current to 60 A raises heating to 720 W.

Related terms:
K

Terms Starting with K

AC & DC

Kilowatt (kW)

A standard SI multiple of the watt equal to 1,000 watts (10³ W) of instantaneous real power. Distinguish kilowatts (kW, how fast electrical energy is being used or generated right now) from kilowatt-hours (kWh, the total volume of energy accumulated over time).

Symbol: kWSI Unit: kilowatt (kW)
Formula: 1 kW = 1,000 W ≈ 1.341 mechanical hp

Example: A 7,200 W Level 2 home EV charger operates at a power rate of 7.2 kW; running it for 5 hours transfers 36 kWh of energy.

Related terms:
AC & DC

Kilowatt-Hour (kWh)

A commercial unit of electrical energy equal to one kilowatt (1,000 W) of real power sustained for one hour (3.6 megajoules). Used globally on utility electricity bills and for rating electric vehicle and home energy storage battery capacity.

Symbol: kWhSI Unit: kilowatt-hour (kWh)
Formula: kWh = (Watts × Hours) ÷ 1,000 = kW × Hours

Example: An EV with a 75 kWh battery pack charging from 20% to 80% State of Charge adds 0.60 × 75 = 45 kWh of energy.

Related terms:
AC & DC

Kirchhoff's Circuit Laws (KCL & KVL)

Two foundational conservation laws governing all electrical networks: Kirchhoff's Current Law (KCL, conservation of charge) states that the algebraic sum of currents entering any node equals the sum leaving; Kirchhoff's Voltage Law (KVL, conservation of energy) states that the directed sum of potential differences around any closed circuit loop equals zero.

Symbol: KCL / KVLSI Unit: ampere (A) / volt (V)
Formula: ∑ I_in = ∑ I_out (KCL) | ∑ V_loop = 0 (KVL)

Example: In a series loop with a 12 V supply and two resistors dropping 4 V and 8 V, KVL confirms +12 V − 4 V − 8 V = 0 V.

Related terms:
L

Terms Starting with L

DC

Light-Emitting Diode (LED) & Forward Voltage

A semiconductor diode that emits narrow-spectrum light via electroluminescence when forward-biased. Because an LED has a steep exponential current-voltage curve above its characteristic forward voltage (Vf ≈ 1.8–2.2 V for red/amber, 3.0–3.4 V for blue/white), it requires a series current-limiting resistor or constant-current driver to prevent thermal runaway.

Symbol: LED / V_fSI Unit: volt (V) / milliampere (mA)
Formula: R_series = (V_supply − V_f) ÷ I_f

Example: Driving a white LED (Vf = 3.2 V, If = 20 mA) from a 12 V DC source requires R = (12 − 3.2) ÷ 0.020 = 440 Ω (standard E12 value: 470 Ω).

Related terms:
AC & DC

Lockout / Tagout (LOTO) & Safe Isolation

The mandatory electrical safety procedure of disconnecting an energy source, physically locking the isolator or breaker in the OFF position with a personal padlock and warning tag, and verifying absence of voltage across all conductors (Line-to-Neutral, Line-to-Earth, Line-to-Line) using a dedicated voltage indicator proved on a known live source before and after testing (Prove-Test-Prove).

Symbol: LOTOSI Unit: 0 V verified (Dead Testing)

Example: Before replacing a circuit breaker or motor terminal block, the electrician locks off the upstream isolator and performs a 3-step Prove-Test-Prove dead verification.

Related terms:
M

Terms Starting with M

DC

Maximum Power Point Tracking (MPPT)

An active DC-to-DC conversion algorithm inside solar charge controllers and PV string inverters that tracks the non-linear I-V curve of a solar array as irradiance and cell temperature change, locking onto the exact voltage (Vmp) and current (Imp) where P = V × I is maximized.

Symbol: MPPTSI Unit: ampere (A) / watt (W)
Formula: I_bat_out ≈ (P_pv_in × η_mppt) ÷ V_bat

Example: A 400 W solar module at 40 V Vmp feeding a 12.8 V battery via a 98% efficient MPPT controller delivers ~30.6 A into the battery, whereas a PWM controller pulls the module down to battery voltage and loses over half the power.

Related terms:
AC & DC

Motor Full-Load Current (FLA vs. FLC)

Full-Load Amps (FLA) is the actual rated current stamped on a motor’s manufacturer nameplate at rated shaft output, voltage, and frequency. Under NFPA 70 NEC Article 430.6(A)(1), branch-circuit conductors and short-circuit/ground-fault breakers are sized using NEC Table Full-Load Current (FLC, e.g., Table 430.248/430.250) rather than nameplate FLA, whereas thermal overload relays are set strictly from nameplate FLA.

Symbol: FLA ↔ FLCSI Unit: ampere (A)
Formula: I_FLA (3φ) = (P_out_W) ÷ (√3 × V_LL × η × PF)

Example: A 10 hp 460 V 3-phase motor has an NEC Table 430.250 FLC of 14 A (requiring a 17.5 A minimum conductor ampacity at 125%), while its thermal overload is set from its 13.1 A nameplate FLA.

Related terms:
AC

Motor Synchronous Speed & Slip

Synchronous speed (n_s) is the rotational speed of the stator’s magnetic field in an AC motor, determined solely by supply frequency (f) and the number of magnetic poles (P). In an induction motor, the rotor must turn slightly slower than n_s so magnetic flux lines cut the rotor bars to induce torque; that fractional speed difference is called slip (s).

Symbol: n_s / sSI Unit: RPM / percent (%)
Formula: n_s (RPM) = (120 × f) ÷ P | s (%) = ((n_s − n_r) ÷ n_s) × 100%

Example: A 4-pole motor on 60 Hz has a synchronous speed of (120 × 60) ÷ 4 = 1,800 RPM (or 1,500 RPM at 50 Hz); running at 1,750 RPM gives 2.78% slip.

Related terms:
AC & DC

Multimeter Overvoltage Category (CAT II / CAT III / CAT IV)

IEC 61010-1 safety classifications defining the transient impulse energy an electrical test instrument and its probes can withstand without arc-over: CAT II covers plug-connected appliance outlets; CAT III covers fixed building distribution boards, feeders, and 3-phase motors; and CAT IV covers utility service entrances, overhead lines, and meter sockets.

Symbol: IEC 61010 CATSI Unit: volt (V)

Example: A meter rated CAT III 600 V / CAT IV 300 V is engineered to survive an 6,000 V transient spike on a distribution panel busbar without exploding in the user’s hand.

Related terms:
N

Terms Starting with N

AC

Neutral & Phase Conductors (Live/Line ↔ Hot)

The active current-carrying conductors of an AC circuit: the ungrounded phase conductor is termed the Line or Live conductor (L / L1–L3, harmonized Brown/Black/Grey) under IEC 60364 / BS 7671 and the Hot or Ungrounded conductor (Black/Red) under NFPA 70 NEC. The Neutral conductor (N, IEC Blue / NEC White or Grey) is the grounded return conductor that completes the circuit back to the source in single-phase and unbalanced three-phase systems.

Symbol: N & L / HotSI Unit: ampere (A) / volt (V)
Formula: I_N (3φ balanced linear load) = 0 A

Example: In a single-phase 120 V (NEC) or 230 V (IEC) circuit, the neutral conductor carries the exact same fundamental load current as the hot/line conductor.

Related terms:
O

Terms Starting with O

AC & DC

Ohm (Ω)

The SI derived unit of electrical resistance, reactance, and impedance. One ohm is the resistance between two points of a conductor when a constant potential difference of 1 volt applied between them produces a current of 1 ampere.

Symbol: ΩSI Unit: ohm (Ω)
Formula: 1 Ω = 1 V ÷ 1 A

Example: A resistive heating element that draws 10 A from a 230 V supply has a hot operating resistance of 23 Ω.

Related terms:
AC & DC

Ohm's Law

The foundational law of circuit analysis stating that the electric current (I) flowing through a linear ohmic conductor is directly proportional to the applied voltage (V) and inversely proportional to its resistance (R). In AC circuits with reactive components, Ohm’s Law generalizes to V = I × Z using impedance.

Symbol: V = I × RSI Unit: V, A, Ω
Formula: V = I × R | I = V ÷ R | R = V ÷ I

Example: Applying 24 V across a 12 Ω resistive load produces a steady current of I = 24 ÷ 12 = 2 A.

Related terms:
AC & DC

Overcurrent

Any current in excess of the rated current of equipment or the ampacity of a conductor. Overcurrent is divided into two distinct conditions: an overload (excessive current confined to the normal conductive path, such as a stalled motor) and a fault current (short circuit or ground/earth fault outside the normal path).

Symbol: I > InSI Unit: ampere (A)
Related terms:
P

Terms Starting with P

DC

Peak Sun Hours (PSH)

The equivalent number of hours per day during which solar irradiance averages 1,000 W/m² (1 kW/m², the Standard Test Condition irradiance used to rate solar panels). Peak Sun Hours are not the same as total daylight hours and are used to convert array STC wattage into expected daily energy yield.

Symbol: PSHSI Unit: hours / day (kWh/m²/day)
Formula: Daily Wh = Array STC Watts × Peak Sun Hours × Derate Factor

Example: A 1,000 W solar array in a region with 4.5 Peak Sun Hours and an 0.80 system derate factor generates 1,000 × 4.5 × 0.80 = 3,600 Wh (3.6 kWh) per day.

Related terms:
AC

Peak, Peak-to-Peak & RMS Voltage

For a sinusoidal AC waveform, Peak Voltage (V_pk) is the maximum amplitude from zero to crest; Peak-to-Peak Voltage (V_pp = 2 × V_pk) is the full voltage swing from positive crest to negative trough seen on an oscilloscope; and RMS Voltage (V_rms = V_pk ÷ √2) is the effective DC-equivalent heating voltage.

Symbol: V_pk / V_pp / V_rmsSI Unit: volt (V)
Formula: V_pk = V_rms × √2 ≈ 1.414 × V_rms | V_pp = 2 × V_pk ≈ 2.828 × V_rms

Example: A 230 V RMS European AC mains supply reaches a peak of ±325.3 V and a peak-to-peak swing of 650.5 V.

Related terms:
AC

Phase Angle (φ)

The angular time displacement between the voltage waveform and the current waveform in an AC circuit, expressed in degrees (°) or radians. In purely resistive circuits φ = 0°; in inductive circuits current lags voltage (0° < φ ≤ +90°); and in capacitive circuits current leads voltage (−90° ≤ φ < 0°).

Symbol: φ / θSI Unit: degrees (°) / radians (rad)
Formula: φ = arccos(P ÷ S) = arctan((X_L − X_C) ÷ R) | PF = cos φ

Example: An inductive motor load operating at a 0.85 lagging power factor has a phase displacement angle of φ = arccos(0.85) = 31.79°.

Related terms:
DC

Photovoltaic (PV) Cell & Solar Array

A semiconductor photodiode (typically monocrystalline silicon) that converts solar photons directly into DC electricity via the photovoltaic effect. Individual PV cells (~0.5–0.6 V each) are wired in series to form a solar module (panel), and modules are combined in series strings (adding voltage) and parallel strings (adding current) to form a PV array.

Symbol: PVSI Unit: watt-peak (Wp / kWp)
Formula: V_string = N_series × V_module | I_array = N_parallel × I_module

Example: Eight 400 Wp panels (Vmp = 40 V, Imp = 10 A) wired as 2 parallel strings of 4 in series (4S2P) produce an array rated at 3,200 Wp (160 V Vmp, 20 A Imp).

Related terms:
DC

Polarity (Positive & Negative)

The fixed directional orientation of electrical potential in a direct current (DC) circuit, designating the higher-potential terminal as positive (+) and the lower-potential return terminal as negative (−). Reversing DC polarity on polarized components (electrolytic capacitors, diodes, BMS boards, PV inputs) can cause immediate short-circuit damage.

Symbol: + / −SI Unit: volt (V)
Formula: Conventional Current: flows from Positive (+) to Negative (−)

Example: Standard DC wiring conventions use red insulation for positive (+) and black (or blue/white per regional DC code) for negative (−).

Related terms:
AC & DC

Power

The instantaneous rate at which electrical energy is transferred by a circuit or converted into mechanical work, heat, or light, measured in watts (W = J/s). In DC circuits P = V × I; in AC circuits real working power includes the power factor (P = V × I × PF for 1φ, or P = √3 × V_LL × I_L × PF for 3φ).

Symbol: PSI Unit: watt (W)
Formula: P = V × I = I² × R = V² ÷ R (DC)

Example: A 120 V circuit carrying 15 A to a resistive load delivers P = 120 × 15 = 1,800 W (1.8 kW) of real power.

Related terms:
AC

Power Factor

The dimensionless ratio of real working power (W) to apparent power (VA) in an AC circuit, equal to the cosine of the phase angle (cos φ) for sinusoidal waveforms. A low power factor (<0.85) means higher current must flow through cables and transformers to deliver the same real power, increasing I²R losses and voltage drop.

Symbol: PF / cos φSI Unit: ratio (0 to 1)
Formula: PF = P (W) ÷ S (VA) = cos φ

Example: A motor consuming 4 kW of real power while drawing 5 kVA of apparent power operates at a power factor of 4 ÷ 5 = 0.80.

Related terms:
Q

Terms Starting with Q

AC

Quality Factor (Q) & Resonant Frequency

In an inductive-capacitive (RLC) AC circuit, the resonant frequency (f₀) is the frequency at which inductive reactance equals capacitive reactance (X_L = X_C), cancelling reactive impedance. The Quality Factor (Q) measures the sharpness of resonance—defined as the ratio of energy stored to energy dissipated per cycle.

Symbol: Q / f₀SI Unit: dimensionless (Q) / hertz (Hz)
Formula: f₀ = 1 ÷ (2π × √(L × C)) | Q_series = (1 ÷ R) × √(L ÷ C)

Example: A series LC filter with L = 1 mH and C = 10 µF resonates at f₀ = 1 ÷ (2π × √(10⁻³ × 10⁻⁵)) = 1,591.5 Hz.

Related terms:
R

Terms Starting with R

AC

Reactance

The non-resistive opposition offered to alternating current by inductance (inductive reactance, X_L = 2πfL) or capacitance (capacitive reactance, X_C = 1/(2πfC)). Unlike resistance, pure reactance shifts the phase angle between voltage and current by 90° and alternately stores and returns energy without dissipating real power as heat.

Symbol: XSI Unit: ohm (Ω)
Formula: X = X_L − X_C = 2πfL − 1 ÷ (2πfC)

Example: When inductive reactance X_L equals capacitive reactance X_C at the resonant frequency, net reactance X becomes zero.

Related terms:
AC

Real, Reactive and Apparent Power

The three components of the AC power triangle: Real Power (P, in W or kW) performs irreversible work or heating; Reactive Power (Q, in VAR or kVAR) oscillates between source and load to magnetize inductive coils or charge capacitors; and Apparent Power (S, in VA or kVA) is their vector hypotenuse (S = √(P² + Q²)).

Symbol: P, Q, SSI Unit: W, VAR, VA
Formula: S² = P² + Q² | P = S × cos φ | Q = S × sin φ

Example: A plant load with 30 kW real power and 40 kVAR inductive reactive power draws 50 kVA of apparent power (√(30² + 40²) = 50 kVA) at 0.60 PF.

Related terms:
AC & DC

Residual Current Device (GFCI ↔ RCD / RCBO)

Cross-standard earth-leakage shock protection: Continuously compares outgoing line current with returning neutral current and trips when earth leakage exceeds rated residual current (IΔn). In North America (NEC 210.8 / UL 943), a Class A GFCI trips between 4–6 mA for personnel protection (while GFPE trips at 30 mA for equipment). In IEC 60364-4-41 / BS 7671 Reg. 411.3.3, an RCD (or combined overcurrent RCBO) rated IΔn ≤ 30 mA provides additional shock protection, while 100–300 mA Type S devices provide fire protection (with Type AC, A, F, and B waveform ratings for DC/EV loads).

Symbol: GFCI ↔ RCD / RCBOSI Unit: milliampere (mA)
Formula: R_A × I_Δn ≤ 50 V (IEC / BS 7671 TT earthing touch-voltage limit)

Example: A 30 mA Type A RCD/RCBO (IEC) or 5 mA Class A GFCI breaker (NEC) disconnects in milliseconds if current leaks through a person to earth.

Related terms:
AC & DC

Resistance

The opposition a material offers to the flow of electric current in both DC and AC circuits, converting electrical energy irreversibly into heat (P = I²R). Unlike impedance (Z)—which includes frequency-dependent AC reactance—pure resistance depends on conductor resistivity, length, cross-sectional area, and temperature.

Symbol: RSI Unit: ohm (Ω)
Formula: R = V ÷ I | R = ρ × L ÷ A

Example: 50 m of 4 mm² copper wire at 20 °C has a one-way DC resistance of (0.01724 × 50) ÷ 4 = 0.2155 Ω.

Related terms:
AC & DC

Resistivity (ρ)

An intrinsic material property that quantifies how strongly a given metal or insulator opposes electric current per unit length and cross-sectional area at a standard reference temperature (20 °C). Annealed copper has a lower resistivity than aluminum, meaning aluminum requires ~1.6× the cross-sectional area for equal resistance.

Symbol: ρSI Unit: Ω·mm²/m (or Ω·m)
Formula: ρ_Cu (20 °C) ≈ 0.01724 Ω·mm²/m | ρ_Al (20 °C) ≈ 0.02826 Ω·mm²/m

Example: Because aluminum has ~64% higher resistivity than copper, an aluminum feeder must be roughly two AWG sizes larger to match copper voltage drop.

Related terms:
AC & DC

Resistor & Color Code

A passive two-terminal electronic component engineered to introduce a precise electrical resistance into a circuit for current limiting, voltage division, or signal biasing. Axial through-hole resistors mark their nominal resistance, tolerance (e.g., ±1% or ±5%), and temperature coefficient (ppm/K) using standardized IEC 60062 color bands.

Symbol: RSI Unit: ohm (Ω) / watt (W)
Formula: P_rating ≥ 2 × (I² × R) (Standard 2× thermal derating practice)

Example: A 4-band resistor marked Yellow-Violet-Red-Gold decodes to 47 × 10² = 4,700 Ω (4.7 kΩ) with ±5% tolerance.

Related terms:
AC

Root Mean Square (RMS)

The effective quadratic mean value of a time-varying AC voltage or current—defined as the equivalent DC value that dissipates the exact same average thermal power in a purely resistive load. All nominal AC utility voltages (120 V, 230 V, 277 V, 400 V, 480 V) are specified as RMS figures.

Symbol: V_rms / I_rmsSI Unit: volt (V) / ampere (A)
Formula: V_rms = V_peak ÷ √2 ≈ 0.7071 × V_peak (Pure sine wave)

Example: A 120 V RMS sine wave has a peak voltage of 120 × √2 = 169.7 V and a peak-to-peak voltage of 339.4 V.

Related terms:
S

Terms Starting with S

AC & DC

Selectivity (Discrimination)

The graded coordination of overcurrent or residual-current protective devices wired in series so that when a fault occurs downstream, only the protective device immediately upstream of the fault operates—leaving main incoming breakers and healthy parallel feeders energized.

Symbol: CoordinationSI Unit: ampere (A) / milliseconds (ms)

Example: Time-delayed 100 mA Type S upstream RCDs provide selectivity above instantaneous 30 mA final-circuit RCBOs.

Related terms:
AC & DC

Series vs. Parallel Circuits

The two fundamental circuit topologies: In a series circuit, components share a single current path (current I is identical everywhere, voltages divide across components, and resistances add: R_eq = R₁ + R₂ + ...). In a parallel circuit, components connect across the same two nodes (voltage V is identical across every branch, branch currents add, and conductances add: 1/R_eq = 1/R₁ + 1/R₂ + ...).

Symbol: R_eqSI Unit: ohm (Ω) / volt (V) / ampere (A)
Formula: Series: R_eq = ∑ R_i | Parallel: R_eq = 1 ÷ ∑(1 ÷ R_i)

Example: Two 100 Ω resistors wired in series yield 200 Ω; wired in parallel they yield 50 Ω.

Related terms:
AC & DC

Short Circuit

An unintended negligible-resistance connection between two or more conductors operating at different potentials (such as line-to-neutral, phase-to-phase, or positive-to-negative), unleashing a fault current many times larger than normal load current that must be interrupted in milliseconds to prevent fire or arc-flash damage.

Symbol: I_scSI Unit: kiloampere (kA)
Formula: I_sc (3φ sym) = V_LL ÷ (√3 × Z_total)

Example: A bolted phase-to-neutral short circuit on a circuit with 0.05 Ω source impedance at 230 V draws I_sc = 230 ÷ 0.05 = 4,600 A (4.6 kA).

Related terms:
AC & DC

Siemens (S)

The SI derived unit of electric conductance, susceptance, and admittance—equal to the reciprocal of one ohm (1 S = 1 Ω⁻¹ = 1 A/V, historically called the mho). A conductor has a conductance of 1 siemens if a potential difference of 1 volt drives 1 ampere of current through it.

Symbol: SSI Unit: siemens (S)
Formula: 1 S = 1 A ÷ 1 V = 1 ÷ 1 Ω

Example: A parallel busbar network with a total resistance of 0.002 Ω has a conductance of 1 ÷ 0.002 = 500 S.

Related terms:
AC

Single-Phase Power

An AC power distribution system using a single alternating voltage waveform—supplied either via one phase and one neutral conductor (230 V 50 Hz in IEC regions) or a center-tapped 120/240 V split-phase transformer winding (in North America)—used for residential homes and light commercial branch circuits.

Symbol: 1φSI Unit: watt (W) / volt (V)
Formula: P = V × I × PF | I = P ÷ (V × PF)

Example: A 230 V single-phase circuit carrying 16 A at PF = 0.95 delivers 230 × 16 × 0.95 = 3,496 W.

Related terms:
DC

Solar Charge Controller (MPPT vs. PWM)

The DC regulator between a solar PV array and a battery bank that prevents overcharging. Pulse-Width Modulation (PWM) controllers simply switch the PV array directly onto the battery bus (forcing panel voltage down to battery voltage), whereas MPPT controllers use a step-down DC-DC converter to harvest 15%–30% more energy and allow high-voltage PV series strings.

Symbol: MPPT ↔ PWMSI Unit: ampere (A) / volt (V)
Formula: I_controller_min ≥ 1.25 × I_sc_array ( PWM ) or (P_array ÷ V_bat_min) × 1.25 ( MPPT )

Example: A 2,400 W solar array charging a 48 V battery bank produces 2,400 ÷ 48 = 50 A nominal, requiring at least a 60 A or 65 A MPPT charge controller.

Related terms:
DC

Solar Open-Circuit Voltage (Voc) & Short-Circuit Current (Isc)

Two critical solar module nameplate ratings measured at Standard Test Conditions (1,000 W/m², 25 °C cell): Open-Circuit Voltage (Voc) is the maximum voltage with zero load connected, which rises significantly in freezing winter temperatures and governs the maximum number of panels allowed in series before exceeding the inverter/MPPT input rating. Short-Circuit Current (Isc) is the maximum current at zero volts, multiplied by 1.25× (or 1.56× under NEC 690.8) to size PV conductors and fuses.

Symbol: V_oc / I_scSI Unit: volt (V) / ampere (A)
Formula: V_oc_max = V_oc_STC × N_series × [1 + (T_min − 25 °C) × β_Voc]

Example: Ten modules with Voc = 49 V and β_Voc = −0.28%/°C reach 490 × [1 + (−15 − 25) × (−0.0028)] = 544.9 V at −15 °C.

Related terms:
DC

State of Charge (SoC)

The remaining usable charge in a battery expressed as a percentage of its current full capacity (0% = empty, 100% = full; SoC = 100% − DoD). Accurate SoC tracking on flat-voltage LiFePO4 batteries requires coulomb counting (integrating current over time via a shunt monitor) rather than resting voltage alone.

Symbol: SoCSI Unit: percent (%)
Formula: SoC (%) = 100% − DoD (%)

Example: After drawing 35 Ah from a fully charged 100 Ah battery, the battery is at 35% Depth of Discharge and 65% State of Charge.

Related terms:
AC & DC

Stranded vs. Solid Conductors (IEC 60228 Class 1 / 2 / 5)

Conductor construction classifications: Solid conductors (IEC 60228 Class 1) use a single solid metal wire for permanent fixed building wiring in small gauges; stranded conductors (Class 2, typically 7 or 19 strands) provide pull flexibility in conduit feeders; and flexible fine-stranded cables (Class 5 & 6) resist vibration fatigue in machinery, solar leads, and battery interconnects but require crimp ferrules or listed pressure-plate terminals.

Symbol: Class 1 / 2 / 5SI Unit: mm² / AWG

Example: Terminating a fine-stranded Class 5 battery or control wire directly under a bare set-screw lug without a ferrule crushes strands and creates a high-resistance hot spot.

Related terms:
AC & DC

Surge Protective Device (SPD)

A protective device (utilizing Metal Oxide Varistors or gas discharge tubes) wired in parallel with the supply that clamps transient overvoltages caused by lightning strikes or grid switching and diverts surge current safely to earth. Classified into Type 1 (service entrance / lightning current), Type 2 (distribution board), and Type 3 (point-of-use equipment protection) under both UL 1449 / NEC Article 242 and IEC 61643.

Symbol: SPD / U_pSI Unit: kilovolt (kV) / kiloampere (kA)
Formula: U_p (Voltage Protection Level) < Impulse Withstand Voltage (U_w) of protected equipment

Example: Installing a Type 2 SPD with short, straight connecting leads (< 0.5 m total) inside a main distribution panel clamps switching surges below 1.5 kV.

Related terms:
T

Terms Starting with T

AC & DC

Temperature Coefficient of Resistance (α)

The fractional change in electrical resistance of a material per degree Celsius of temperature change from a reference temperature (usually 20 °C). Pure metals like copper and aluminum have a positive temperature coefficient (resistance increases as conductors heat up under load), increasing voltage drop at 75 °C or 90 °C operating temperatures.

Symbol: αSI Unit: 1 / °C (or K⁻¹)
Formula: R(T) = R₂₀ × [1 + α₂₀ × (T − 20 °C)] (α_Cu ≈ 0.00393 /°C, α_Al ≈ 0.00403 /°C)

Example: A copper cable with 1.00 Ω resistance at 20 °C increases to 1.00 × [1 + 0.00393 × (75 − 20)] = 1.216 Ω at 75 °C—nearly 22% higher.

Related terms:
AC & DC

Thermal Derating

The mandatory reduction of a cable’s base table current-carrying capacity (ampacity) when installed in high ambient temperatures (Ca), bundled or grouped with other current-carrying circuits (Cg), or surrounded by thermal building insulation (Ci) that restricts heat dissipation.

Symbol: Ca / Cg / CiSI Unit: factor (0 to 1)
Formula: I_z_derated = I_table × C_a × C_g × C_i (must satisfy I_z_derated ≥ I_n)

Example: Three circuits bundled in conduit inside a 40 °C plant room may retain only 65% to 70% of their 30 °C single-circuit table ampacity.

Related terms:
AC

Three-Phase Power

A polyphase AC generation and distribution system using three sinusoidal voltages of equal magnitude separated in phase by 120 electrical degrees (L1, L2, L3). Three-phase systems create a naturally rotating magnetic field for industrial motors and transmit √3 (1.732) times more power with less conductor mass than single-phase distribution.

Symbol: 3φSI Unit: kilowatt (kW) / kVA
Formula: P = √3 × V_LL × I_L × PF | V_LL = √3 × V_LN (Wye / Star)

Example: A balanced 400 V three-phase load drawing 25 A per line at 0.90 PF consumes 1.732 × 400 × 25 × 0.90 = 15.59 kW.

Related terms:
AC

Transformer

A static electromagnetic machine that transfers AC electrical power between two or more circuits via mutual magnetic induction in a laminated core, stepping voltage up or down in direct proportion to the winding turns ratio (N_p : N_s) while stepping current in the inverse ratio and conserving apparent power (kVA).

Symbol: T / kVASI Unit: volt-ampere (VA / kVA)
Formula: V_p ÷ V_s = N_p ÷ N_s = I_s ÷ I_p

Example: A transformer with 1,000 primary turns and 100 secondary turns steps 240 V AC down to 24 V AC (10:1 turns ratio).

Related terms:
AC

Transformer Impedance (%Z) & Fault Current

The percentage of rated primary voltage that must be applied to a transformer to circulate full-load rated current when the secondary terminals are short-circuited. Transformer %Z limits the maximum symmetrical short-circuit fault current available at the secondary busbar.

Symbol: %Z / Z_puSI Unit: percent (%)
Formula: I_sc_max = I_FL_secondary ÷ (%Z ÷ 100)

Example: A 500 kVA 400 V 3-phase transformer (I_FL = 721.7 A) with %Z = 4% can deliver a maximum secondary short-circuit current of 721.7 ÷ 0.04 = 18,042 A (18.04 kA).

Related terms:
AC & DC

Transistor (MOSFET / IGBT / BJT)

A three-terminal active semiconductor device used to amplify signals or switch electrical power rapidly. Power MOSFETs (voltage-controlled via Gate-Source voltage with low on-state resistance R_DS(on)) dominate low-voltage DC converters and BMS switches, while IGBTs and SiC MOSFETs switch high-voltage power in solar inverters, VFDs, and EV traction drives.

Symbol: Q / MOSFETSI Unit: volt (V) / ampere (A)
Formula: P_conduction (MOSFET) = I_D² × R_DS(on)

Example: A power MOSFET with R_DS(on) = 4 mΩ (0.004 Ω) carrying 25 A dissipates only 25² × 0.004 = 2.5 W of conduction heat.

Related terms:
AC

True-RMS

A digital sampling measurement algorithm used in professional multimeters and clamp meters that computes the exact root-mean-square heating value of any AC waveform—regardless of whether it is a pure sine wave or distorted by harmonics from VFDs, phase-cut dimmers, square-wave inverters, or switch-mode rectifiers.

Symbol: TRMSSI Unit: volt (V) / ampere (A)
Formula: I_TRMS = √( (1/T) × ∫ i(t)² dt )

Example: An inexpensive average-responding meter can read 10% to 40% low on a non-linear VFD or LED driver load, whereas a True-RMS instrument reads the true thermal current.

Related terms:
U

Terms Starting with U

AC & DC

Undervoltage & Voltage Tolerance (Brownout)

A sustained or temporary drop in supply voltage below the nominal equipment utilization tolerance (such as ANSI C84.1 Range A ±5% or EN 50160 ±10%). Undervoltage causes constant-power loads (like induction motors and switch-mode power supplies) to draw higher current, leading to overheating, contactor chatter, or low-voltage inverter cutout.

Symbol: ΔU%SI Unit: volt (V) / percent (%)
Formula: I_motor ≈ P_mech ÷ (√3 × V_LL × η × PF) (Current rises as V_LL sags)

Example: On a 230 V ±10% supply (207 V minimum), excessive branch cable voltage drop can push terminal voltage below 198 V and stall motor contactors.

Related terms:
V

Terms Starting with V

AC & DC

Volt (V)

The SI derived unit of electric potential, electric potential difference (voltage), and electromotive force, defined as one joule of energy transferred per coulomb of charge (1 V = 1 J/C = 1 W/A). Distinguish the unit (volt, V) from the physical quantity (voltage, V or U).

Symbol: VSI Unit: volt (V)
Formula: 1 V = 1 W ÷ 1 A = 1 A × 1 Ω = 1 J ÷ 1 C

Example: Standard household branch circuits operate at 120 V nominal in North America and 230 V nominal across Europe, the UK, and Australia.

Related terms:
AC

Volt-Ampere (VA / kVA) & Volt-Ampere Reactive (VAR)

The specialized SI-coherent units used in AC power engineering to distinguish apparent power (volt-ampere, VA or kVA) and reactive power (volt-ampere reactive, VAR or kVAR) from active real power (watt, W or kW), even though all three share the dimensional product of volts × amperes.

Symbol: VA / VARSI Unit: volt-ampere (VA) / var (VAR)
Formula: 1 kVA = 1,000 VA | P (kW) = S (kVA) × PF

Example: A 100 kVA distribution transformer feeding a load with 0.85 power factor delivers 85 kW of real power and 52.7 kVAR of reactive power.

Related terms:
AC & DC

Voltage

The electrical potential difference between two points in a circuit, representing the work or energy transferred per unit of electric charge (1 V = 1 J/C) that drives electric current through a load. In international IEC 60364 standards, nominal line-to-line voltage is denoted by U and line-to-earth voltage by U₀; in North American NEC practice, V or E is used.

Symbol: V / U / ESI Unit: volt (V)
Formula: V = I × R | V = P ÷ I (DC)

Example: Doubling the voltage across a fixed resistor doubles the current and quadruples the power dissipated (P = V²/R).

Related terms:
AC & DC

Voltage Divider

A passive linear circuit of two or more series impedances connected across a voltage source that produces an output voltage (V_out) equal to a fixed fraction of the input voltage (V_in). Widely used for sensor signal conditioning, ADC reference scaling, and potentiometer controls—not for powering heavy loads, which pull down the divided node voltage.

Symbol: V_out / V_inSI Unit: volt (V)
Formula: V_out = V_in × (R₂ ÷ (R₁ + R₂))

Example: Two series resistors R₁ = 30 kΩ and R₂ = 10 kΩ connected across a 12 V DC supply produce an unloaded output voltage of 12 × (10 ÷ 40) = 3.0 V.

Related terms:
AC & DC

Voltage Drop

The reduction in voltage between the power supply origin and the load terminals caused by load current flowing through the internal resistance and inductive reactance of the circuit conductors. Both NFPA 70 (NEC 210.19 Informational Note) and IEC 60364-5-52 / BS 7671 Section 525 generally recommend keeping branch-circuit drop within 3% and total feeder + branch drop within 5%.

Symbol: V_drop / ΔVSI Unit: volt (V) or percent (%)
Formula: ΔV (1φ / DC) = 2 × I × L × (R cos φ + X sin φ) | ΔV (3φ) = √3 × I × L × (R cos φ + X sin φ)

Example: A 20 A load at the end of a 40 m run of 4 mm² copper on 230 V drops 7.0 V (3.04%), requiring an upsize to 6 mm² copper (4.67 V, 2.03%) to stay under 3%.

Related terms:
W

Terms Starting with W

AC & DC

Watt (W)

The SI derived unit of active (real) power, defined as one joule of energy transferred, converted, or dissipated per second (1 W = 1 J/s = 1 V × 1 A in DC or at unity power factor).

Symbol: WSI Unit: watt (W)
Formula: 1 W = 1 J / s = 1 V × 1 A (DC) | 1,000 W = 1 kW

Example: A 100 W LED floodlight consumes 0.1 kW of instantaneous power and uses 1 kWh of energy every 10 hours of operation.

Related terms:
AC

Wye (Star) vs. Delta Three-Phase Connection

The two standard winding configurations for three-phase transformers, generators, and motors: A Wye (Star, Y) connection joins one end of each of the three phase windings at a common central neutral point, providing both line-to-line voltage (V_LL) and line-to-neutral voltage (V_LN = V_LL / √3, such as 400/230 V or 208/120 V). A Delta (Δ) connection links the three windings in a closed triangle with no neutral point, where phase voltage equals line voltage and line current equals √3 × phase current.

Symbol: Y (Star) ↔ Δ (Delta)SI Unit: volt (V) / ampere (A)
Formula: Wye (Y): V_LL = √3 × V_LN, I_L = I_phase | Delta (Δ): V_LL = V_phase, I_L = √3 × I_phase

Example: A 400/230 V Wye distribution transformer supplies 400 V line-to-line for 3-phase motors and 230 V line-to-neutral for single-phase lighting and sockets.

Related terms:
Z

Terms Starting with Z

DC

Zener Diode & Voltage Reference

A specially doped silicon semiconductor diode engineered to operate reliably in reverse breakdown once reverse voltage reaches a precise Zener voltage (V_Z). Widely used with a series current-limiting resistor to provide a stable DC voltage reference, overvoltage clamping on microcontroller inputs, or gate-source protection on MOSFETs.

Symbol: V_ZSI Unit: volt (V)
Formula: R_series = (V_in − V_Z) ÷ (I_Z + I_load)

Example: A 5.1 V Zener diode clamps an analog sensor input line so transients above 5.1 V are shunted safely through the series resistor.

Related terms:
Apply These Concepts

Put electrical terminology into practice with VoltCalc’s interactive engineering calculators, unit converters, and step-by-step technical guides.

Voltage & Potential Difference

Solve circuit voltage, line-to-load voltage drop, and AC RMS/peak relationships.

Current & Amperage

Convert load wattage to circuit amperage and size branch-circuit overcurrent protection.

Resistance, Reactance & Impedance

Analyze DC conductor resistance, series/parallel resistor networks, and AC impedance.

Electrical Power & Energy

Calculate active power (kW), apparent power (kVA), power factor, and energy consumption (kWh).

Battery Capacity & Energy Storage

Model battery runtime, Ah vs. Wh capacity, Depth of Discharge (DoD), and inverter draw.

Solar PV & Renewable Energy

Size photovoltaic arrays, MPPT charge controllers, battery banks, and off-grid inverters.

Wire Gauge, Cables & Conductors

Compare AWG and IEC 60228 metric mm² cable sizes for ampacity and voltage drop compliance.

Circuit Protection, Grounding & Earthing

Verify breaker sizing, protective conductor cross-section, and short-circuit fault withstand.