kW to HP Converter (Kilowatts to Horsepower)
Convert kilowatts (kW) to mechanical horsepower (1 hp = 745.7 W), metric horsepower (1 PS = 735.5 W), and electrical horsepower for IEC and NEMA motors.
Step-by-step calculation
- Input Power = 7.5 kW (7500 W)
- Mechanical HP (1 hp = 745.7 W) = 7.5 kW ÷ 0.7457 = 10.058 HP
- Metric Horsepower (1 PS = 735.5 W) = 7.5 kW ÷ 0.7355 = 10.197 PS
- Electrical HP (746.0 W/HP) = 7.5 kW ÷ 0.7460 = 10.054 HP
Formula & mathematical explanation
Input definitions
| Symbol | Parameter | Unit | Engineering meaning & standards relevance |
|---|---|---|---|
| P_kW | Power in Kilowatts | kW | Shaft or electrical power in kilowatts (kW). |
| Type | Horsepower Standard | Selection | Select NEMA/Imperial mechanical HP (745.7 W), DIN metric PS (735.5 W), or electrical HP (746 W). |
| η | Efficiency (η) | % | Use 100% if converting shaft output kW directly; enter motor efficiency (e.g., 90%) if converting electrical input kW to shaft HP. |
Standard IEC Motor kW to NEMA Horsepower (HP) Cross-Reference
| IEC Standard (kW) | Exact Mechanical HP | Exact Metric PS | Nearest NEMA Motor Rating |
|---|---|---|---|
| 0.37 kW | 0.496 HP | 0.503 PS | 1/2 HP |
| 0.55 kW | 0.738 HP | 0.748 PS | 3/4 HP |
| 0.75 kW | 1.006 HP | 1.020 PS | 1 HP |
| 1.1 kW | 1.475 HP | 1.496 PS | 1.5 HP |
| 1.5 kW | 2.012 HP | 2.039 PS | 2 HP |
| 2.2 kW | 2.950 HP | 2.991 PS | 3 HP |
| 3.7 kW / 4.0 kW | 4.962 / 5.364 HP | 5.031 / 5.438 PS | 5 HP |
| 5.5 kW | 7.376 HP | 7.478 PS | 7.5 HP |
| 7.5 kW | 10.058 HP | 10.197 PS | 10 HP |
| 11 kW | 14.751 HP | 14.956 PS | 15 HP |
| 15 kW | 20.115 HP | 20.394 PS | 20 HP |
| 18.5 kW | 24.809 HP | 25.153 PS | 25 HP |
| 22 kW | 29.502 HP | 29.912 PS | 30 HP |
Worked example
Matching a 7.5 kW IEC Motor to a NEMA Horsepower Rating
Convert a standard 7.5 kW IEC 60034 induction motor into NEMA mechanical horsepower and metric PS.
- Divide 7.5 kW by 0.7457 kW/HP: 7.5 ÷ 0.7457 = 10.058 HP (NEMA 10 HP frame).
- Metric horsepower note: 7.5 kW ÷ 0.7355 kW/PS = 10.197 PS.
Assumptions
- Both kW and HP values represent mechanical shaft output power when Efficiency η = 100%.
- 1 mechanical HP = 745.7 W (0.7457 kW); 1 metric PS = 735.5 W (0.7355 kW); 1 electrical HP = 746.0 W.
- When Efficiency η < 100%, input electrical kW is multiplied by η to obtain mechanical shaft HP.
Limitations
- IEC metric motor frames and NEMA inch motor frames have different shaft heights and mounting dimensions even when kW and HP ratings match.
- Does not calculate motor full-load current (use the Motor Current Calculator for amps).
How it works
Divides kilowatts (kW) by the exact watt-per-horsepower definition: 0.7457 kW (745.7 W) for Imperial/NEMA mechanical horsepower, 0.7355 kW (735.5 W) for European metric horsepower (PS/CV), or 0.746 kW for electrical horsepower.
When to use it
- Cross-referencing European/IEC motor datasheets (rated in kW) with North American NEMA replacement motors (rated in HP).
- Converting generator, pump, compressor, and EV traction motor kW specifications into horsepower.
Practical real-world applications
- Industrial Motor Replacement: Selecting a 10 HP NEMA motor to replace a 7.5 kW IEC pump motor.
- EV & Automotive Specs: Translating a 250 kW electric vehicle drivetrain rating into 335.26 mechanical HP (339.90 PS).
Original Editorial Review & Technical Evaluation
Converts kilowatts to mechanical (745.7 W), metric (735.5 W), and electrical (746 W) horsepower with a complete IEC-to-NEMA standard motor cross-reference table.
Industrial maintenance engineers, motor control designers, mechanical engineers, and automotive technicians.
- Supports Mechanical HP (745.7 W), Metric PS/CV (735.5 W), and Electrical HP (746 W).
- Displays all three horsepower standards simultaneously in the breakdown.
- Includes a 13-row IEC 60034 (kW) to NEMA MG-1 (HP) standard motor frame lookup table.
Accuracy & methodology: Uses standard 745.7 W/hp and 735.5 W/PS conversion factors.
What to verify independently: Check motor nameplate efficiency and service factor against IEC 60034-30 or NEMA MG-1.
Common mistakes
- Confusing mechanical HP (745.7 W) with metric PS (735.5 W), which differs by 1.4%.
- Using motor shaft HP directly to calculate line amps without dividing by motor efficiency (η) and power factor (cos φ).
Safety & code notice
When sizing motor branch-circuit conductors and overload relays under NEC Article 430, use NEC Table 430.248 / 430.250 Full-Load Current tables based on horsepower rather than nameplate watts.
Frequently asked questions
Related Unit Converters
HP to kW Converter (Horsepower to Kilowatts)
Convert mechanical horsepower (HP) and metric PS into kilowatts (kW) and watts.
Electrical & Thermal Power Converter (W, kW, MW, HP, BTU/hr)
Convert between watts, kilowatts, megawatts, horsepower, metric PS, and BTU/hr.
kW to Watts Converter (Kilowatts to Watts)
Convert kilowatts (kW) to watts (W), megawatts, and mechanical horsepower (HP).
Watts to Amps Converter
Convert active power in watts (W) to current in amps (A) for DC and AC circuits.
Related Calculators
Motor Power Calculator
Calculate motor shaft output power in kW and HP, speed, and full-load torque.
Motor Current Calculator
Calculate full-load motor current, speed, starting inrush, and overload trip.
Motor Sizing Calculator
Size an electric motor from load power or shaft torque with standard ratings.
Three Phase Power Calculator
Calculate real, apparent, and reactive power or line current in 3-phase systems.
Related Engineering Guides
Recommended Tools & Instruments

Klein Tools CL800 Digital Clamp Meter
Wide-jaw auto-ranging clamp meter with inrush capture for motor and compressor starting currents.
- Inrush current capture — see the starting surge that trips breakers, not just the running current.
- Wide jaw opening — accepts larger conductors and bundled cables that slim clamps cannot.
- Auto-ranging true-RMS measurement — fast readings you can trust on non-linear loads.

Fluke 325 True-RMS Clamp Meter
Clamp-on AC/DC current measurement in tight panels, with true-RMS accuracy and a CAT III 600 V rating.
- AC and DC current measurement — covers mains circuits, battery banks and solar strings with one tool.
- Clamp-on measurement — read current without disconnecting or disturbing the circuit.
- Slim jaw profile — slides into crowded panels where bulky clamps will not fit.

Fluke 1587 FC Insulation Multimeter
Insulation testing and full multimeter functions in one instrument, with selectable test voltages up to 1000 V.
- Insulation test voltages from 50 V to 1000 V — matches the test voltage to the equipment instead of using one fixed setting.
- Full true-RMS multimeter functions — voltage, current, resistance and continuity without a second instrument.
- Wireless result logging — builds a trend over time so you can see insulation degrading before it fails.

Fluke 117 True-RMS Multimeter
The everyday electrician's meter: true-RMS AC measurement, non-contact voltage detection and a CAT III 600 V rating in a compact body.
- True-RMS AC measurement — accurate readings on the electronic loads that fool cheaper average-sensing meters.
- Built-in non-contact voltage detection — confirm a circuit is live before you put a probe anywhere near it.