Skip to content

Wire Size Calculator

Find the minimum conductor cross-section for a given current, length, and allowable drop.

Wire Size Calculator

Enter System Voltage, Load Current, One-way Length to see the result.

Formula

A = (2 × ρ × L × I) ÷ V_drop (single phase)

Input definitions

InputSymbolUnitWhat it means
System VoltageVVThe potential difference across the circuit or component, in volts.
Load CurrentIAThe current flowing through the circuit, in amperes.
One-way LengthLmOne-way conductor length from the supply to the load; the calculation includes the return path or three-phase multiplier.
Allowable DropΔV%%Your chosen maximum voltage drop as a percentage of supply voltage; this is a design input, not a universal code limit.
Conductor Materialρ—Conductor material used to choose the resistivity in the voltage-drop calculation.
Phase——Select single-phase or balanced three-phase operation; use line-to-line voltage for three-phase calculations.

Assumptions

  • The displayed formula and selected mode define the simplified model. Only the inputs shown are included; unstated installation conditions are not inferred.
  • Enter each value in the unit printed beside its input. Any conversion needed by the formula is handled as shown in the calculation steps.
  • Entered ratings, efficiencies, loads and component values are treated as constant for the operating point or time period being estimated.

Limitations

  • No code tables are applied: ampacity, derating for grouping, ambient temperature and installation method must be checked separately.
  • Harmonics, non-linear loads, motor starting current and protective-device trip characteristics are not modelled.
  • The result is a planning estimate for a single operating point, not a load study or a design verification.

Safety and code notice

Use this tool for learning and preliminary calculations. Always verify electrical designs against applicable local codes and a qualified professional. VoltCalc provides planning estimates, not code compliance — see the methodology and safety disclaimer.

How it works

The conductor must be large enough that voltage drop stays within the target. This calculation gives the minimum cross-sectional area; you then choose the next larger standard size.

When to use it

Use it for long cable runs where voltage drop, not ampacity, governs the size.

Put the numbers to work with the Voltage Drop Calculator, Electrical Load Calculator and Circuit Breaker Size Calculator.

Common mistakes

Sizing on voltage drop alone and ignoring the cable's current-carrying capacity (ampacity).

Frequently asked questions

Which matters more — ampacity or voltage drop?
Both must be satisfied. Take the larger of the two results.
Why choose the next standard size up?
Standard sizes come in fixed steps, so you round up to the nearest available conductor.

Related guides

All products →
Blue-handled Klein Katapult wire stripper with a black steel cutting head and safety icons
Klein Tools

Klein Tools 11063W Wire Stripper and Cutter

A self-adjusting wire stripper and cutter that handles solid and stranded conductors from 8–18 AWG without nicking the copper.

  • Self-adjusting action — squeeze once and the tool sets itself to the conductor size, so strips are repeatable.
  • Clean strip without nicking — protects the copper, which is what keeps a termination reliable long term.
  • Built-in cutter and plier nose — you can cut, strip and twist without swapping tools.
Pros
  • Self-adjusting action is fast on repetitive work
  • Clean strips without nicking conductors
  • Doubles as a cutter and plier
Cons
  • Bulkier than a simple stripping tool in tight boxes
Check PriceView details

VoltCalc may earn a commission when you buy through links on this page, at no extra cost to you. Prices and availability are shown as a guide only and may change.

Black Klein crimping pliers with red and black handles and colour-coded crimp slots
Klein Tools

Klein Tools 3005CR Ratcheting Crimper

A ratcheting crimping tool for insulated and non-insulated terminals from 22–10 AWG, with a full-cycle release.

  • Ratcheting mechanism — the tool stays locked until the crimp is fully formed, so a weak grip cannot produce a weak joint.
  • 22–10 AWG range — covers the terminal sizes used in most panel and control wiring.
  • Insulated and non-insulated terminals — one tool handles both, so you are not carrying two.
Pros
  • The ratchet prevents half-formed crimps
  • Handles both insulated and bare terminals
  • Comfortable over long runs
Cons
  • A single tool cannot cover every terminal type — some connectors need dedicated dies
Check PriceView details

VoltCalc may earn a commission when you buy through links on this page, at no extra cost to you. Prices and availability are shown as a guide only and may change.

Black and orange Klein CL800 clamp meter with case, test leads, thermocouple and batteries
Klein Tools

Klein Tools CL800 Digital Clamp Meter

An auto-ranging true-RMS clamp meter with a wide jaw, inrush current measurement and a CAT IV 300 V rating.

  • Inrush current capture — see the starting surge that trips breakers, not just the running current.
  • Wide jaw opening — accepts larger conductors and bundled cables that slim clamps cannot.
  • Auto-ranging true-RMS measurement — fast readings you can trust on non-linear loads.
Pros
  • Inrush mode helps diagnose motor starting problems
  • Wide jaw accepts larger conductors
  • Auto-ranging keeps field work quick
Cons
  • Bulkier than a pocket clamp meter
  • Lower CAT IV rating than some competitors
Check PriceView details

VoltCalc may earn a commission when you buy through links on this page, at no extra cost to you. Prices and availability are shown as a guide only and may change.

VoltCalc may earn a commission when you buy through links on this page, at no extra cost to you. Prices and availability are shown as a guide only and may change.