Reactance Calculator
Calculate inductive or capacitive reactance from frequency and component value.
Step-by-step calculation
- Angular frequency ω = 2π × 60 Hz = 376.99 rad/s
- X_L = 2π × 60 Hz × 0.1 H = 37.6991 Ω
Formula
Input definitions
| Symbol | Input | Unit | Meaning & code relevance |
|---|---|---|---|
| Type | Reactance Type | — | Engineering input parameter for reactance type, evaluated in real-time by the solver. |
| f | Frequency | Hz | Alternating current supply frequency in hertz (50 Hz IEC / 60 Hz North America) governing inductive and capacitive reactance. |
| L/C | Component Value (mH or µF) | mH / µF | Engineering input parameter for component value (mh or µf) measured in mH / µF, evaluated in real-time by the solver. |
Worked example
100 mH Inductor at 60 Hz
Calculate inductive reactance at utility frequency.
- L = 0.1 H
- X_L = 2π × 60 × 0.1 = 37.699 Ω
Assumptions
- The applied signal is a single-frequency pure sine wave at frequency f (in Hz).
- Inductance (mH) and capacitance (µF) are ideal lumped values without parasitic winding resistance or ESR.
- Magnetic core saturation and dielectric frequency roll-off are ignored.
Limitations
- Calculates only reactive opposition (X_L or X_C); to combine with series resistance (R), use the Impedance Calculator.
- Non-sinusoidal waveforms contain harmonic frequencies, each of which sees a different reactance.
How it works
Inductive reactance increases linearly with frequency (2πfL), whereas capacitive reactance drops inversely with frequency (1 / 2πfC).
When to use it
- Calculating inductive reactance (X_L = 2πfL) of chokes, line reactors, motor windings, and transformer inductances at 50 Hz, 60 Hz, or RF frequencies.
- Finding capacitive reactance (X_C = 1 ÷ 2πfC) of power-factor correction capacitors, AC motor run capacitors, and EMI filter caps.
- Designing passive RC or RL high-pass/low-pass filters and determining the resonant frequency where X_L equals X_C.
Practical real-world applications
- Calculating the 60 Hz capacitive reactance and current draw of a 45 µF HVAC compressor run capacitor (X_C = 58.95 Ω, drawing 4.07 A at 240 V).
- Sizing a 3% or 5% AC line reactor in millihenrys (mH) ahead of a Variable Frequency Drive (VFD) to limit harmonic current distortion (IEEE 519).
- Designing capacitive voltage-dropper power supplies and AC coupling networks in low-power electronic control boards.
Original Editorial Review & Technical Evaluation
Computes inductive reactance (X_L = 2πfL) and capacitive reactance (X_C = 1 ÷ 2πfC) at power-line (50/60 Hz) or RF/switching frequencies.
Power-factor correction engineers, filter circuit designers, and RF/analog technicians evaluating frequency-dependent impedance.
- Solves inductive reactance, capacitive reactance, and net series LC reactance across Hz, kHz, and MHz bands
- Determines series resonant frequency f₀ = 1 ÷ (2π√(LC)) where X_L and X_C cancel
- Supports standard microhenry/millihenry/henry and picofarad-to-farad component prefixes
Accuracy & methodology: Applies ideal lossless linear reactance equations assuming pure sinusoidal excitation and constant inductance/capacitance values. Core saturation in inductors, dielectric ESR, and parasitic trace capacitance at high MHz frequencies are not modeled. Computational standards →
What to verify independently: Verify inductor saturation current (I_sat), capacitor ripple-current ratings, and tolerance drift across operating temperature from manufacturer datasheets.
Put the numbers to work with the Ohm's Law Calculator, Impedance Calculator and Power Factor Calculator. For the background behind the numbers, read Understanding Power Factor and Why It Matters and How to Choose Electronic Components.
Common mistakes
- Entering inductance in millihenrys (mH) or capacitance in microfarads (µF) directly into 2πfL or 1/(2πfC) without converting to base Henrys (H) and Farads (F).
- Forgetting the factor of 2π (6.2832) and multiplying frequency f instead of angular frequency ω = 2πf.
- Treating inductive reactance X_L and capacitive reactance X_C as having the same phase sign instead of subtracting them (X_net = |X_L − X_C|) in series RLC circuits.
Safety & code notice
Calculator results are planning estimates. Always verify electrical designs against applicable local codes, standards (NEC / IEC), and consult a qualified professional.
Frequently asked questions
Related Calculators
Ohm's Law Calculator
Calculate voltage, current, resistance, and power in DC or resistive AC circuits.
Impedance Calculator
Calculate total AC impedance (Z) and phase angle from resistance and reactance.
Power Factor Calculator
Calculate power factor, phase angle, real power (kW), kVA, and reactive kVAR.
Capacitor Energy Calculator
Calculate stored electrostatic energy in joules and charge from C and voltage.
Related Unit Converters
Watts to Amps Converter
Convert active power in watts (W) to current in amps (A) for DC and AC circuits.
Amps to Watts Converter
Convert current in amps (A) to active power in watts (W) for DC and AC systems.
Volts to Watts Converter
Convert voltage (V) and current (A) into real power in watts for DC and AC loads.
Related Engineering Guides
Recommended Bench Multimeters & Soldering Equipment for Component Work
Verify component resistance and capacitance out-of-circuit with an auto-ranging True-RMS multimeter and use a temperature-controlled ESD-safe soldering station for clean joints.

AstroAI DM6000AR True-RMS Digital Multimeter
A true-RMS 6000-count meter with temperature, capacitance and a CAT III 600 V rating — the budget option for DIY, hobby and student work.
- True-RMS AC measurement — accurate readings on the distorted, non-sinusoidal waveforms that switch-mode supplies, dimmers and inverters produce, which is where average-sensing meters quietly mislead.
- 6000-count display with 0.1 mV and 0.1 µA resolution — more resolution on low-voltage and low-current work than a typical 2000-count budget meter, so small changes are visible rather than rounded away.
- CAT III 600 V and CAT II 1000 V safety rating — rated for the transient energy of distribution panels and fixed wiring, not just bench work.

Fluke 117 True-RMS Multimeter
The everyday electrician's meter: true-RMS AC measurement, non-contact voltage detection and a CAT III 600 V rating in a compact body.
- True-RMS AC measurement — accurate readings on the electronic loads that fool cheaper average-sensing meters.
- Built-in non-contact voltage detection — confirm a circuit is live before you put a probe anywhere near it.
- CAT III 600 V safety rating — rated for the transient energy you meet in distribution panels and fixed wiring.

Klein Tools MM700 Auto-Ranging Multimeter
Auto-ranging true-RMS meter with a CAT IV 600 V rating and a tough, drop-tested housing.
- Auto-ranging — connect the probes and read the value, with no range dial to set first.
- True-RMS AC measurement — trustworthy numbers on drives, supplies and electronic lighting.
- CAT IV 600 V rating — the highest common safety category, covering outdoor and service-entrance work.

Weller WE1010NA Digital Soldering Station
A 70 W temperature-controlled soldering station with a digital readout for consistent joints.
- 70 W element — recovers heat quickly on larger joints instead of stalling mid-solder.
- Digital temperature setpoint — repeatable settings job to job, rather than a vague dial position.
- Adjustable temperature range — works for fine electronics and heavier control wiring with one station.