Skip to content
VoltCalcElectrical Calculators & Tools

Voltage Calculator

Calculate supply or load terminal voltage (DC or AC RMS) from current, resistance, or wattage.

Voltage
120 V
V = I × R
How we got here

Step-by-step calculation

  1. V = 5 A × 24 Ω
  2. V = 120 V
Voltage (kV)0.12 kV
Power (P = I²R)600 W

Formula

V = I × R | V = P ÷ I | V = √(P × R)

Input definitions

SymbolInputUnitMeaning & code relevance
ICurrentASteady-state operating load current in amperes; compare with NEC Table 310.16 or IEC 60364-5-52 conductor ampacity.
RResistanceΩDC or equivalent AC ohmic resistance in ohms (Ω) at operating temperature.
PPower (optional)WActive electrical or mechanical power transfer (W) dissipated or delivered to the load.

Worked example

15 A Load Through 8 Ω

Determine supply or terminal voltage across an 8 Ω heating element drawing 15 A.

  1. V = I × R = 15 × 8 = 120 V nominal (allowable ±5% ANSI C84.1 utility tolerance: 114 V–126 V).
Result: 120 V

Assumptions

  • Current and resistance represent steady-state DC or single-phase AC RMS values prior to feeder voltage drop.
  • Nominal utility supply voltages carry typical operating tolerances (±5% ANSI C84.1 Range A in North America; ±10% IEC 60038 globally).
  • When solving from power (P = V × I), unity power factor (PF = 1.0) and constant resistance at operating temperature are assumed.

Limitations

  • Does not account for inductive or capacitive reactance in AC motors, transformers, or ballasts.
  • Supply line voltage drop between the panel and the load terminals is not deducted automatically.

How it works

Solves for DC or single-phase AC RMS supply and load terminal voltage using current & resistance (V = I × R), power & current (V = P ÷ I), or power & resistance (V = √(P × R)), benchmarking against ±5% ANSI / ±10% IEC supply tolerances.

When to use it

  • Determining the required DC or single-phase AC RMS supply voltage (V = P ÷ I) from an appliance’s nameplate wattage and current rating.
  • Calculating the voltage drop or potential difference across a known resistor or shunt element carrying a measured current (V = I × R).
  • Finding the maximum safe operating voltage across a fixed-ohm load resistor given its maximum power dissipation rating (V = √(P × R)).

Practical real-world applications

  • Verifying whether an industrial heater element rated at 4,500 W and 18.75 A is designed for a 240 V single-phase bus rather than a 208 V commercial wye supply.
  • Calculating the millivolt or volt output signal across a 250 Ω precision PLC input resistor driven by a 4–20 mA process transmitter (1.0 V to 5.0 V).
  • Checking load terminal voltage against ANSI C84.1 (±5% Range A) or IEC 60038 (±10%) utilization tolerances during equipment commissioning.

Original Editorial Review & Technical Evaluation

Reviewed by VoltCalc Engineering Editorial

Determines required supply or load terminal voltage (V) across DC and purely resistive AC RMS circuits from current, resistance, or active load wattage inputs.

Intended Users

Field commissioning technicians checking supply vs. load terminal potential, panel builders, and equipment installers diagnosing under-voltage or over-voltage issues.

Key Engineering Features
  • Automatically selects V = I × R, V = P ÷ I, or V = √(P × R) from whichever two known parameters are provided
  • Cross-checks triple-input entries and flags physically inconsistent V–I–R–P combinations
  • Evaluates nominal DC and AC RMS load voltage prior to feeder and branch-circuit drop deductions

Accuracy & methodology: Treats entered power and current as steady-state DC or single-phase AC RMS quantities operating at unity power factor (PF = 1.0) against nominal ±5% ANSI C84.1 or ±10% IEC 60038 supply tolerances. Inductive/capacitive phase angles and line voltage drop between panel and load terminals are not subtracted here. Computational standards →

What to verify independently: Measure actual open-circuit and loaded supply voltage at the equipment terminals with a CAT-rated True-RMS voltmeter against ANSI C84.1 (±5% Range A) or IEC 60038 (±10%) tolerances.

Standards referenced:ANSI C84.1IEC 60038IEC 61010

Put the numbers to work with the Ohm's Law Calculator, Current Calculator and Resistance Calculator. For the background behind the numbers, read Ohm's Law Explained: Voltage, Current and Resistance and How to Choose a Multimeter.

Common mistakes

  • Using V = P ÷ I on AC motors or fluorescent/LED drivers without dividing by Power Factor (cos φ), which understates the required circuit voltage or apparent power.
  • Confusing total supply voltage to earth with the voltage drop (ΔV = I × R_wire) across a single series component or cable segment.
  • Assuming a 240 V rated resistive appliance will draw the same power on a 208 V network (operating voltage drops by 13.3%, reducing wattage by 25%).

Safety & code notice

Calculator results are planning estimates. Always verify electrical designs against applicable local codes, standards (NEC / IEC), and consult a qualified professional.

Frequently asked questions

Related Calculators

Related Unit Converters

Related Engineering Guides

Recommended Clamp Meters & Voltage Testers for This Task

Affiliate links — helps keep VoltCalc free

Verify live load current with a CAT III/IV True-RMS clamp meter, prove de-energized status with a non-contact voltage detector, and compare source vs. load terminal voltage under full operating current.

Fluke 117 True-RMS Multimeter
FlukeGlobal (CAT III 600V IEC 61010)

Fluke 117 True-RMS Multimeter

The everyday electrician's meter: true-RMS AC measurement, non-contact voltage detection and a CAT III 600 V rating in a compact body.

Type: True-RMS digital multimeterSafety rating: CAT III 600 VMeasures: Voltage, resistance, continuity, capacitance, frequency
  • True-RMS AC measurement — accurate readings on the electronic loads that fool cheaper average-sensing meters.
  • Built-in non-contact voltage detection — confirm a circuit is live before you put a probe anywhere near it.
  • CAT III 600 V safety rating — rated for the transient energy you meet in distribution panels and fixed wiring.
Check Current Price
Klein Tools MM700 Auto-Ranging Multimeter
Klein ToolsGlobal (CAT IV 600V IEC 61010)

Klein Tools MM700 Auto-Ranging Multimeter

Auto-ranging true-RMS meter with a CAT IV 600 V rating and a tough, drop-tested housing.

Type: Auto-ranging true-RMS digital multimeterSafety rating: CAT IV 600 VDisplay: Backlit LCD
  • Auto-ranging — connect the probes and read the value, with no range dial to set first.
  • True-RMS AC measurement — trustworthy numbers on drives, supplies and electronic lighting.
  • CAT IV 600 V rating — the highest common safety category, covering outdoor and service-entrance work.
Check Current Price
Fluke 1AC-II VoltAlert Non-Contact Voltage Tester
FlukeGlobal (90–1000V AC CAT IV 1000V IEC 61010)

Fluke 1AC-II VoltAlert Non-Contact Voltage Tester

A quick live-wire check you can keep in a shirt pocket — CAT IV 1000 V rated.

Type: Non-contact voltage testerVoltage range: 90–1000 V ACSafety rating: CAT IV 1000 V
  • Non-contact detection — confirms voltage is present without any contact or exposed metal.
  • Audible and visual indication — clear beep and bright glow, so you can confirm while looking elsewhere.
  • CAT IV 1000 V rating — safety category suited to service entrances and outdoor conductors.
Check Current Price
Klein Tools NCVT-3P Non-Contact Voltage Tester
Klein ToolsGlobal (12–1000V AC CAT IV 1000V IEC 61010)

Klein Tools NCVT-3P Non-Contact Voltage Tester

Dual-range voltage tester with an integrated flashlight for working in dark panels.

Type: Non-contact voltage testerVoltage range: 12–1000 V ACExtras: Built-in flashlight, dual range
  • Built-in flashlight — no separate torch needed when you are working inside a dark enclosure.
  • Dual sensitivity ranges — narrows detection so adjacent wiring causes fewer false positives.
  • 12–1000 V AC detection — covers everything from control circuits up to mains voltage.
Check Current Price
Affiliate Disclosure: VoltCalc may earn a commission from qualifying purchases made through product links at no extra cost to you. Product specs and availability are for reference and may change.Affiliate Disclosure →