Electrical Symbols

Circuit symbols are the universal shorthand of electrical schematics and wiring diagrams. Use this chart to identify power sources, protective devices, passive components, semiconductors, and grounding symbols.

Side-by-Side Schematic Electrical Symbols: North American (ANSI/IEEE Std 315) vs. International (IEC 60617)

Compare North American NEMA / ANSI / IEEE schematic conventions directly alongside International IEC 60617 / BS EN 60617 representations and reference designators.

Protective Earth / Equipment Ground

PE / EGC / GND
North America (ANSI / IEEE)
⏚ (GND / EGC)
EGC / GND (ANSI Y32.2)
International (IEC 60617)
⏚ (PE / CPC)
PE / CPC (IEC 60617-02-15)

Reference zero-potential connection to earth electrode or equipment bonding bar.

Resistor (Fixed)

R
North America (ANSI / IEEE)
—╱╲╱╲╱╲— (Zig-Zag)
R (IEEE Std 315)
International (IEC 60617)
—[ ▭ ]— (Rectangular Box)
R (IEC 60617-04-01)

Passive element providing specific ohmic opposition (R) to current flow; ANSI uses a zig-zag line while IEC 60617 uses a rectangular block.

Capacitor (Non-Polarized / Polarized)

C
North America (ANSI / IEEE)
—| (— (Curved Plate)
C (IEEE Std 315)
International (IEC 60617)
—| |— (Parallel Plates)
C (IEC 60617-04-02)

Stores energy in an electrostatic field; ANSI often shows one curved plate for polarized/general capacitors while IEC uses two equal parallel lines.

Inductor / Winding / Choke

L
North America (ANSI / IEEE)
—⋂⋂⋂⋂— (Looped Scallops)
L (IEEE Std 315)
International (IEC 60617)
—⋂⋂⋂— / —[▬]— (Semicircles / Filled Box)
L (IEC 60617-04-03)

Stores magnetic energy when current flows through a coil winding, opposing changes in current (X_L = 2πfL).

Circuit Breaker (OCPD / MCB / MCCB)

CB / QF / OCPD
North America (ANSI / IEEE)
—⌒— (Curved Arc Contact)
CB / OCPD (ANSI/NEMA)
International (IEC 60617)
—×/— (Crossed Contact Switch)
QF / MCB (IEC 60617-07-13)

Automatic overcurrent protective switch with thermal overload and magnetic short-circuit trip elements.

Residual Current Device (GFCI / RCD)

GFCI / RCD
North America (ANSI / IEEE)
GFCI (5 mA Class A)
GFCI (NEC Art. 100 / 210.8)
International (IEC 60617)
RCD / RCBO (IΔn 30 mA)
RCD / F (IEC 60617-07-18)

Differential core-balance transformer sensing earth leakage current (IΔn) and tripping the switching mechanism.

Fuse (Overcurrent Fusible Link)

FU / F
North America (ANSI / IEEE)
—∿— (S-Curve Link)
FU (IEEE Std 315)
International (IEC 60617)
—[—]— (Rectangle with Line Through)
F (IEC 60617-07-21)

Sacrificial overcurrent protective device whose calibrated element melts under excessive I²t let-through energy.

Transformer (Power / Control)

T / XFMR
North America (ANSI / IEEE)
3||ε (Opposing Inductors)
T / XFMR (ANSI)
International (IEC 60617)
◯̸◯ (Overlapping Circles / Coils)
T (IEC 60617-06-09)

Transfers AC power between primary and secondary circuits via mutual induction; IEC single-line diagrams also use overlapping circles.

Three-Phase Induction Motor

M / MOT
North America (ANSI / IEEE)
( MTR ) / ( M )
MTR (NEMA / NEC Art. 430)
International (IEC 60617)
( M 3~ )
M (IEC 60617-06-04)

Rotating machine converting three-phase AC electrical power into mechanical shaft torque.

Diode / Rectifier

D / VD
North America (ANSI / IEEE)
—|>|— (Filled Triangle)
D / CR (IEEE Std 315)
International (IEC 60617)
—|>|— (Triangle with Center Line)
V / D (IEC 60617-05-03)

Semiconductor PN junction permitting current flow in the forward anode-to-cathode direction.

Related Calculators

Related Unit Converters

Related Engineering Guides

Frequently Asked Questions

There are two primary standards: IEC 60617 (used across Europe, the UK, Asia, and Australia) and ANSI/IEEE Std 315 (used in North America). For example, a resistor is drawn as a rectangle in IEC schematics and as a jagged zigzag line in ANSI schematics.

Related Equipment

Affiliate links — helps keep VoltCalc free
Weller WE1010NA Digital Soldering Station
WellerNorth America (120V AC 60Hz NEMA)

Weller WE1010NA Digital Soldering Station

A 70 W temperature-controlled soldering station with a digital readout for consistent joints.

Type: Digital soldering stationPower: 70 WControl: Digital temperature setpoint
  • 70 W element — recovers heat quickly on larger joints instead of stalling mid-solder.
  • Digital temperature setpoint — repeatable settings job to job, rather than a vague dial position.
  • Adjustable temperature range — works for fine electronics and heavier control wiring with one station.
Check Current Price
Fluke 117 True-RMS Multimeter
FlukeGlobal (CAT III 600V IEC 61010)

Fluke 117 True-RMS Multimeter

The everyday electrician's meter: true-RMS AC measurement, non-contact voltage detection and a CAT III 600 V rating in a compact body.

Type: True-RMS digital multimeterSafety rating: CAT III 600 VMeasures: Voltage, resistance, continuity, capacitance, frequency
  • True-RMS AC measurement — accurate readings on the electronic loads that fool cheaper average-sensing meters.
  • Built-in non-contact voltage detection — confirm a circuit is live before you put a probe anywhere near it.
  • CAT III 600 V safety rating — rated for the transient energy you meet in distribution panels and fixed wiring.
Check Current Price
Klein Tools ET310 Circuit Breaker Finder Kit
Klein ToolsNorth America (120V AC NEMA 5-15 GFCI)

Klein Tools ET310 Circuit Breaker Finder Kit

Finds the breaker feeding a circuit without shutting the panel down — the transmitter plugs into the outlet, the receiver traces it back.

Type: Circuit breaker finder kitIncluded: Receiver, transmitter, light socket adapter, ground adapter, carry caseWiring checks: Open ground, open neutral, open hot, hot/neutral reverse, hot/ground reverse
  • Transmitter and receiver pair — plug the transmitter into the socket, then sweep the receiver across the panel to identify the matching breaker.
  • Wiring status indicator on the transmitter — the same open ground, open neutral, open hot, reversed hot/neutral and reversed hot/ground checks as a standard outlet tester.
  • GFCI test button — trips a GFCI device to confirm it is actually protecting the circuit, not just installed.