Siemens Q230 30-Amp Double-Pole Circuit Breaker
The 30-amp two-pole breaker that feeds an electric dryer, a small AC unit or a water heater.

A 30-amp two-pole QP breaker for 240 V loads such as electric dryers and small air conditioners, with a 10 kA interrupting rating.
- 30 A 240 V common-trip protection
- Sized for 10 AWG dryer & heater circuits
- 10 kAIC interrupting rating
Affiliate Disclosure: VoltCalc may earn a commission from qualifying purchases made through product links at no extra cost to you. Product specs and availability are for reference and may change.
Field Overview
Thirty amps at 240 volts is one of the most familiar circuit sizes in a home, because it is exactly what an electric dryer needs. The Q230 covers that, along with small air conditioners, some water heaters and workshop equipment. It is the middle child of the QP range — bigger than the 20-amp circuits that run your lights, smaller than the 40 and 50-amp feeds for ranges and subpanels, and it turns up on almost every residential job at some point.
Detailed Feature Breakdown
- 30 amps per pole at 120/240 V — the standard feed for an electric dryer or small AC unit.
- Common trip — both poles open together on a fault or overload.
- 10 kA interrupting rating and HACR listing for air conditioning and refrigeration loads.
- Two-pole QP footprint — two adjacent one-inch spaces in a Siemens or Murray panel.
- Accepts copper or aluminium conductors, with the torque value printed on the case.
Performance & Practical Use
A 30-amp two-pole breaker is one of the least eventful parts of an installation: it sits there for a decade and does nothing until the dryer element fails. That reliability is exactly what you want. The practical points are in the wiring. A dryer circuit is usually 10 AWG copper, and if the run is long, voltage drop starts to matter — a dryer that heats slowly on a 60-foot run is often a voltage drop problem rather than a broken appliance. Torque the terminals properly too; a loose 30-amp terminal is a common source of heat damage in panels.
How It Compares
If your appliance nameplate says 40 or 50 amps, do not fit a 30 — step up to the Q240 or Q250. If it is a 240 V load under 20 amps, the Q220 is the cheaper and smaller option.
Pros
- Correct size for the most common dryer circuit
- Common trip and HACR rated
- Copper and aluminium conductor support
- Inexpensive and easy to source
Cons
- No GFCI or AFCI protection built in
- Panel space requirement of two slots is easy to overlook
VoltCalc Verdict
Buy the Q230 when a 30-amp 240 V circuit needs a breaker in a Siemens or Murray panel — a dryer, a small AC, a water heater. It is inexpensive and does the job. Match it to the appliance nameplate and the conductor size rather than to the old breaker you are replacing, because panels are full of breakers that were oversized by a previous owner.