Skip to content
VoltCalcElectrical Calculators & Tools
SiemensCircuit BreakersVerifiedNorth America (120V/240V NEC UL 489)

Siemens Q240 40-Amp Double-Pole Circuit Breaker

A 40-amp two-pole breaker for ranges, larger air conditioners and 32-amp EV charger circuits.

Siemens Siemens Q240 40-Amp Double-Pole Circuit Breaker
4.7(690 reviews)Verified

A 40-amp two-pole QP breaker for 240 V loads including ranges, larger air conditioners and 32-amp EV charging circuits.

Key Features
  • 40 A 240 V double-pole common trip
  • Supports 32 A continuous EV charging
  • Plug-in mounting for Siemens panels
Best for: Ranges, larger air conditioners and 32-amp EV charger circuits.
Skip if: The circuit needs GFCI or AFCI protection, or the load requires 50 amps.
Check Current Price

Affiliate Disclosure: VoltCalc may earn a commission from qualifying purchases made through product links at no extra cost to you. Product specs and availability are for reference and may change.

Field Overview

Forty amps is the size that shows up when a load is genuinely substantial: an electric range, a larger central air conditioner, a welder outlet, or a 32-amp EV charger on a 40-amp circuit. The Q240 handles all of them in a Siemens or Murray panel. It is a two-pole breaker with common trip, and the reason it matters is that the loads behind it draw enough current that a loose termination or an undersized conductor stops being a nuisance and starts being a hazard.

Detailed Feature Breakdown

  • 40 amps per pole at 120/240 V — suitable for ranges, large AC units and 32 A EV charging.
  • Common trip — both poles open together, so neither leg stays live after a fault.
  • 10 kA interrupting rating, HACR rated for air conditioning and refrigeration.
  • Handles larger conductors — 8 AWG copper up to 6–4 AWG for higher-capacity feeds.
  • Two-pole QP footprint for Siemens and Murray load centres.

Performance & Practical Use

This is the breaker for a circuit that is expected to work hard. On an electric range or a 32-amp EV charger it holds a heavy, sustained load for hours without the warmth that would indicate a bad connection — provided, as always, the terminations are torqued to spec. Where people get it wrong is in the conductor: a 40-amp circuit is not a place for 10 AWG, and it is not a place for aluminium without confirming the equipment is rated for it. Get the wire and the torque right and the breaker is the least of your worries for the next twenty years.

How It Compares

If the appliance nameplate calls for a 50-amp circuit, use the Q250. For EV charging, a 40-amp breaker supports a 32-amp charger — the 80% continuous-load rule is what sets that pair.

Pros

  • Right size for ranges, large AC units and 32 A EV charging
  • Common trip and HACR rated
  • Accepts larger conductors for high-demand circuits
  • Reliable and inexpensive

Cons

  • No GFCI protection — a hot tub or pool circuit needs a GFCI breaker instead
  • Requires correctly sized conductors, not just the right breaker

VoltCalc Verdict

Buy the Q240 for a 40-amp 240 V circuit in a Siemens or Murray panel: a range, a large air conditioner or a 32-amp EV charger. It is a simple, reliable part of a properly sized circuit. Size the conductors to the load, respect the 80% rule on continuous loads like EV charging, and torque the terminals — those three things matter far more than the brand of the breaker.

Frequently Asked Questions

An electric range, a larger central air conditioner, a welder outlet or a 32-amp EV charger — anything needing 240 volts at up to 40 amps. The appliance nameplate and the manufacturer's circuit requirements decide the size, not the old breaker in the panel.