Skip to content
VoltCalcElectrical Calculators & Tools
°C / °F / K → °C / °F / KUnits & Thermal

Temperature Converter (°C, °F, Kelvin)

Convert temperatures between Celsius (°C), Fahrenheit (°F), and Kelvin (K) in any direction, with automatic copper and aluminum conductor resistance correction factors.

Converted Result (°F)
77 °F
K = °C + 273.15 | °F = (°C × 1.8) + 32
How we got here

Step-by-step calculation

  1. Celsius: 25 °C
  2. Fahrenheit: 77 °F
  3. Kelvin: 298.15 K
Celsius25 °C
Fahrenheit77 °F
Kelvin298.15 K
Cu Res. Factor (vs 20°C)1.0196×
Al Res. Factor (vs 20°C)1.0201×

Formula & mathematical explanation

K = °C + 273.15 | °F = (°C × 1.8) + 32

Input definitions

SymbolParameterUnitEngineering meaning & standards relevance
TTemperature ValueSelectionTemperature reading to convert.
FromFrom ScaleSelectionInput temperature scale.
ToTo ScaleSelectionOutput temperature scale.

Multi-Scale Electrical Temperature & Conductor Resistance Factor Table

Celsius (°C)Fahrenheit (°F)Kelvin (K)Copper R FactorAluminum R Factor
0 °C32.0 °F273.15 K0.9214×0.9194×
20 °C68.0 °F293.15 K1.0000×1.0000×
25 °C77.0 °F298.15 K1.0197×1.0202×
30 °C86.0 °F303.15 K1.0393×1.0403×
60 °C140.0 °F333.15 K1.1572×1.1612×
75 °C167.0 °F348.15 K1.2162×1.2217×
90 °C194.0 °F363.15 K1.2751×1.2821×

Worked example

Standard Test Conditions (STC) 25°C Across All Three Scales

Convert the 25°C solar panel and battery STC reference temperature to Fahrenheit and Kelvin.

  1. Fahrenheit: (25 × 1.8) + 32 = 77.00 °F.
  2. Kelvin: 25 + 273.15 = 298.15 K.
Result: 25 °C = 77.00 °F = 298.15 K

Assumptions

  • Absolute zero is 0 K = -273.15 °C = -459.67 °F.
  • Copper α = 0.00393 /°C and Aluminum α = 0.00403 /°C at 20°C per IEC 60228.

Limitations

  • Linear resistance coefficients are accurate from -50°C to +200°C; cryogenic temperatures require non-linear Matthiessen models.

How it works

Normalizes the input temperature to degrees Celsius, then computes Fahrenheit, absolute temperature in Kelvin, and the exact resistance temperature multipliers for both copper (α = 0.00393/°C) and aluminum (α = 0.00403/°C) relative to 20°C.

When to use it

  • Converting between °C, °F, and K for semiconductor thermal noise (kT/q), diode Shockley equations, and conductor heating.
  • Calculating the exact copper or aluminum resistance multiplier at any operating temperature relative to 20 °C.

Practical real-world applications

  • Semiconductor Thermal Voltage: Using Kelvin (T = 300 K) to calculate thermal voltage V_T = kT/q ≈ 25.85 mV.
  • Feeder Voltage Drop at 75°C: Applying the 1.216× copper resistance factor when a cable runs at full rated load.

Original Editorial Review & Technical Evaluation

Reviewed by VoltCalc Engineering Editorial

All-in-one °C, °F, and Kelvin converter with built-in copper and aluminum resistance temperature multipliers.

Intended Users

Electrical engineers, electronics designers, and field technicians.

Key Capabilities
  • Bidirectional conversion across Celsius, Fahrenheit, and Kelvin.
  • Computes both Copper and Aluminum resistance multipliers relative to 20°C.

Accuracy & methodology: Exact thermodynamic scales and IEC 60228 alpha coefficients.

What to verify independently: Compare with NEC Chapter 9 Table 8 temperature formulas.

Standards referenced:IEC 60228ISO 80000-5

Common mistakes

  • Using Celsius instead of absolute Kelvin in Boltzmann (kT) or Stefan-Boltzmann (T⁴) thermal radiation equations.
  • Applying a 20 °C temperature coefficient (α₂₀ = 0.00393/°C) to a baseline resistance measured at 25 °C or 75 °C without adjusting the reference temperature.

Safety & code notice

Always verify equipment maximum ambient temperature ratings (typically 40°C / 104°F) inside unventilated enclosures.

Frequently asked questions

Related Unit Converters

Related Calculators

Related Engineering Guides

Recommended Tools & Instruments

Affiliate links — helps keep VoltCalc free
Fluke 117 True-RMS Multimeter
FlukeGlobal (CAT III 600V IEC 61010)

Fluke 117 True-RMS Multimeter

The everyday electrician's meter: true-RMS AC measurement, non-contact voltage detection and a CAT III 600 V rating in a compact body.

Type: True-RMS digital multimeterSafety rating: CAT III 600 VMeasures: Voltage, resistance, continuity, capacitance, frequency
  • True-RMS AC measurement — accurate readings on the electronic loads that fool cheaper average-sensing meters.
  • Built-in non-contact voltage detection — confirm a circuit is live before you put a probe anywhere near it.
  • CAT III 600 V safety rating — rated for the transient energy you meet in distribution panels and fixed wiring.
Check Current Price
Fluke 325 True-RMS Clamp Meter
FlukeGlobal (CAT III 600V / CAT IV 300V IEC 61010)

Fluke 325 True-RMS Clamp Meter

Clamp-on AC/DC current measurement in tight panels, with true-RMS accuracy and a CAT III 600 V rating.

Type: True-RMS clamp meterCurrent: AC and DCSafety rating: CAT III 600 V
  • AC and DC current measurement — covers mains circuits, battery banks and solar strings with one tool.
  • Clamp-on measurement — read current without disconnecting or disturbing the circuit.
  • Slim jaw profile — slides into crowded panels where bulky clamps will not fit.
Check Current Price
Klein Tools NCVT-3P Non-Contact Voltage Tester
Klein ToolsGlobal (12–1000V AC CAT IV 1000V IEC 61010)

Klein Tools NCVT-3P Non-Contact Voltage Tester

Dual-range voltage tester with an integrated flashlight for working in dark panels.

Type: Non-contact voltage testerVoltage range: 12–1000 V ACExtras: Built-in flashlight, dual range
  • Built-in flashlight — no separate torch needed when you are working inside a dark enclosure.
  • Dual sensitivity ranges — narrows detection so adjacent wiring causes fewer false positives.
  • 12–1000 V AC detection — covers everything from control circuits up to mains voltage.
Check Current Price
Klein Tools 11063W Wire Stripper and Cutter
Klein ToolsGlobal / AWG Standard (8–20 AWG NEC & IEC)

Klein Tools 11063W Wire Stripper and Cutter

Self-adjusting stripper that grips, strips and cuts common building wire in one motion.

Type: Self-adjusting wire stripper / cutterCapacity: 8–18 AWG solid, 10–20 AWG strandedHandles: Dual-material, slip-resistant
  • Self-adjusting action — squeeze once and the tool sets itself to the conductor size, so strips are repeatable.
  • Clean strip without nicking — protects the copper, which is what keeps a termination reliable long term.
  • Built-in cutter and plier nose — you can cut, strip and twist without swapping tools.
Check Current Price
Affiliate Disclosure: VoltCalc may earn a commission from qualifying purchases made through product links at no extra cost to you. Product specs and availability are for reference and may change.Affiliate Disclosure →