Temperature Converter (°C, °F, Kelvin)
Convert temperatures between Celsius (°C), Fahrenheit (°F), and Kelvin (K) in any direction, with automatic copper and aluminum conductor resistance correction factors.
Step-by-step calculation
- Celsius: 25 °C
- Fahrenheit: 77 °F
- Kelvin: 298.15 K
Formula & mathematical explanation
Input definitions
| Symbol | Parameter | Unit | Engineering meaning & standards relevance |
|---|---|---|---|
| T | Temperature Value | Selection | Temperature reading to convert. |
| From | From Scale | Selection | Input temperature scale. |
| To | To Scale | Selection | Output temperature scale. |
Multi-Scale Electrical Temperature & Conductor Resistance Factor Table
| Celsius (°C) | Fahrenheit (°F) | Kelvin (K) | Copper R Factor | Aluminum R Factor |
|---|---|---|---|---|
| 0 °C | 32.0 °F | 273.15 K | 0.9214× | 0.9194× |
| 20 °C | 68.0 °F | 293.15 K | 1.0000× | 1.0000× |
| 25 °C | 77.0 °F | 298.15 K | 1.0197× | 1.0202× |
| 30 °C | 86.0 °F | 303.15 K | 1.0393× | 1.0403× |
| 60 °C | 140.0 °F | 333.15 K | 1.1572× | 1.1612× |
| 75 °C | 167.0 °F | 348.15 K | 1.2162× | 1.2217× |
| 90 °C | 194.0 °F | 363.15 K | 1.2751× | 1.2821× |
Worked example
Standard Test Conditions (STC) 25°C Across All Three Scales
Convert the 25°C solar panel and battery STC reference temperature to Fahrenheit and Kelvin.
- Fahrenheit: (25 × 1.8) + 32 = 77.00 °F.
- Kelvin: 25 + 273.15 = 298.15 K.
Assumptions
- Absolute zero is 0 K = -273.15 °C = -459.67 °F.
- Copper α = 0.00393 /°C and Aluminum α = 0.00403 /°C at 20°C per IEC 60228.
Limitations
- Linear resistance coefficients are accurate from -50°C to +200°C; cryogenic temperatures require non-linear Matthiessen models.
How it works
Normalizes the input temperature to degrees Celsius, then computes Fahrenheit, absolute temperature in Kelvin, and the exact resistance temperature multipliers for both copper (α = 0.00393/°C) and aluminum (α = 0.00403/°C) relative to 20°C.
When to use it
- Converting between °C, °F, and K for semiconductor thermal noise (kT/q), diode Shockley equations, and conductor heating.
- Calculating the exact copper or aluminum resistance multiplier at any operating temperature relative to 20 °C.
Practical real-world applications
- Semiconductor Thermal Voltage: Using Kelvin (T = 300 K) to calculate thermal voltage V_T = kT/q ≈ 25.85 mV.
- Feeder Voltage Drop at 75°C: Applying the 1.216× copper resistance factor when a cable runs at full rated load.
Original Editorial Review & Technical Evaluation
All-in-one °C, °F, and Kelvin converter with built-in copper and aluminum resistance temperature multipliers.
Electrical engineers, electronics designers, and field technicians.
- Bidirectional conversion across Celsius, Fahrenheit, and Kelvin.
- Computes both Copper and Aluminum resistance multipliers relative to 20°C.
Accuracy & methodology: Exact thermodynamic scales and IEC 60228 alpha coefficients.
What to verify independently: Compare with NEC Chapter 9 Table 8 temperature formulas.
Common mistakes
- Using Celsius instead of absolute Kelvin in Boltzmann (kT) or Stefan-Boltzmann (T⁴) thermal radiation equations.
- Applying a 20 °C temperature coefficient (α₂₀ = 0.00393/°C) to a baseline resistance measured at 25 °C or 75 °C without adjusting the reference temperature.
Safety & code notice
Always verify equipment maximum ambient temperature ratings (typically 40°C / 104°F) inside unventilated enclosures.
Frequently asked questions
Related Unit Converters
Related Calculators
Voltage Drop Calculator
Calculate AC and DC voltage drop across AWG or metric mm² copper and aluminum runs.
Joule Heating Calculator
Calculate thermal heat energy in joules, calories, and BTU from I²R and time.
Solar Panel Calculator
Calculate solar PV array wattage and panel count from daily kWh and sun hours.
Related Engineering Guides
Recommended Tools & Instruments

Fluke 117 True-RMS Multimeter
The everyday electrician's meter: true-RMS AC measurement, non-contact voltage detection and a CAT III 600 V rating in a compact body.
- True-RMS AC measurement — accurate readings on the electronic loads that fool cheaper average-sensing meters.
- Built-in non-contact voltage detection — confirm a circuit is live before you put a probe anywhere near it.
- CAT III 600 V safety rating — rated for the transient energy you meet in distribution panels and fixed wiring.

Fluke 325 True-RMS Clamp Meter
Clamp-on AC/DC current measurement in tight panels, with true-RMS accuracy and a CAT III 600 V rating.
- AC and DC current measurement — covers mains circuits, battery banks and solar strings with one tool.
- Clamp-on measurement — read current without disconnecting or disturbing the circuit.
- Slim jaw profile — slides into crowded panels where bulky clamps will not fit.

Klein Tools NCVT-3P Non-Contact Voltage Tester
Dual-range voltage tester with an integrated flashlight for working in dark panels.
- Built-in flashlight — no separate torch needed when you are working inside a dark enclosure.
- Dual sensitivity ranges — narrows detection so adjacent wiring causes fewer false positives.
- 12–1000 V AC detection — covers everything from control circuits up to mains voltage.

Klein Tools 11063W Wire Stripper and Cutter
Self-adjusting stripper that grips, strips and cuts common building wire in one motion.
- Self-adjusting action — squeeze once and the tool sets itself to the conductor size, so strips are repeatable.
- Clean strip without nicking — protects the copper, which is what keeps a termination reliable long term.
- Built-in cutter and plier nose — you can cut, strip and twist without swapping tools.