Siemens Q250 50-Amp Double-Pole Circuit Breaker

A 50-amp two-pole breaker for ranges, spa feeds, subpanels and 40-amp EV charging.

Siemens Siemens Q250 50-Amp Double-Pole Circuit Breaker
4.8(950 reviews)Verified

A 50-amp two-pole QP breaker for 240 V loads including ranges, subpanel feeds and 40-amp EV charging circuits.

Key Features
  • 50 A 240 V double-pole common trip
  • Accepts up to #4 AWG Cu/Al conductors
  • Ideal for 40 A Level 2 EV circuits
Best for: Ranges, subpanel feeds and 40-amp EV charger circuits.
Skip if: The circuit requires GFCI protection — the QF250A is the correct device.
Check Current Price

Affiliate Disclosure: VoltCalc may earn a commission from qualifying purchases made through product links at no extra cost to you. Product specs and availability are for reference and may change.

Field Overview

Fifty amps is where residential circuits start to carry real power. It is the standard feed for an electric range in many homes, the usual size for a hot tub or spa circuit once GFCI protection is added, a common subpanel feed in a garage or workshop, and the circuit size that lets you run a 40-amp EV charger. The Q250 covers all of those in a Siemens or Murray panel, and because it is often feeding a subpanel or a high-demand appliance, the installation details around it matter more than they do on a lighting circuit.

Detailed Feature Breakdown

  • 50 amps per pole at 120/240 V — ranges, spa circuits, subpanel feeds and 40 A EV charging.
  • Common trip — both poles open together on overload or fault.
  • 10 kA interrupting rating and HACR listing.
  • Accepts 6 AWG copper or 4 AWG aluminium, torqued to the value on the case.
  • Two-pole QP footprint for Siemens and Murray load centres.

Performance & Practical Use

A 50-amp breaker feeding a range or a 40-amp charger runs warm under load and should stay that way — warm, not hot. Any heat at the terminal is a torque or conductor problem, and on a 50-amp circuit that is worth investigating rather than ignoring. If you are feeding a subpanel, remember the breaker protects the feeder conductors and the subpanel is protected downstream; the two need to be coordinated so a fault in the subpanel is cleared by the right device.

How It Compares

For a 40-amp charger, this is the breaker you want. For a 48-amp charger you would need a 60-amp circuit. If the load is only 40 amps, the Q240 saves nothing but panel space and cable cost.

Pros

  • Suitable for ranges, subpanels and 40 A EV charging
  • Common trip and HACR rated
  • Accepts 6 AWG copper conductors
  • Widely available and inexpensive

Cons

  • No built-in GFCI — spa, pool and some outdoor circuits need a GFCI breaker
  • Heavy loads demand correct conductor sizing and torque

VoltCalc Verdict

The Q250 is the workhorse for high-demand 240 V residential circuits. Buy it for a range, a spa feed with GFCI protection, a subpanel or a 40-amp EV charger. The one thing to get right is the GFCI requirement: if the circuit feeds a hot tub, pool or outdoor equipment, you need a GFCI breaker, not this plain version — see the QF250A.

Frequently Asked Questions

Electric ranges, spa and hot tub circuits (with GFCI protection), garage or workshop subpanel feeds, and EV charging at 40 amps. Anything needing 240 volts at up to 50 amps falls in this range.